  1 ? 2003 integrated device technology, inc. all rights reserved. product specifications subject to change without notice. dsc-5939/9 june 2003 idt and the idt logo are registered trademarks of integrated device technology, inc commercial and industrial temperature ranges 3.3v multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824 bits 1,179,648 bits 2,359,296 bits idt72v51433 idt72v51443 idt72v51453 features: ? ? ? ? ? choose from among the following memory density options: idt72v51433 ? ? ? ? ? total available memory = 589,824 bits idt72v51443 ? ? ? ? ? total available memory = 1,179,648 bits idt72v51453 ? ? ? ? ? total available memory = 2,359,296 bits ? ? ? ? ? configurable from 1 to 16 queues ? ? ? ? ? 166 mhz high speed operation (6ns cycle time) ? ? ? ? ? 3.7ns access time ? ? ? ? ? queues may be configured at master reset from the pool of total available memory in blocks of 512 x 18 or 1,024 x 9 ? ? ? ? ? independent read and write access per queue ? ? ? ? ? user programmable via serial port ? ? ? ? ? default multi-queue device configurations -idt72v51433: 2,048 x 18 x 16q or 4,096 x 9 x 16q -idt72v51443: 4,096 x 18 x 16q or 8,192 x 9 x 16q -idt72v51453: 8,192 x 18 x 16q or 16,384 x 9 x 16q ? ? ? ? ? 100% bus utilization, read and write on every clock cycle ? ? ? ? ? individual, active queue flags ( ov , ff , pae , paf ) ? ? ? ? ? 8 bit parallel flag status on both read and write ports ? ? ? ? ? shows pae and paf status of 8 queues ? ? ? ? ? direct or polled operation of flag status bus ? ? ? ? ? global bus matching - (all queues have same input bus width and output bus width) ? ? ? ? ? user selectable bus matching options: - x18in to x18out - x9in to x18out - x18in to x9out - x9in to x9out ? ? ? ? ? fwft mode of operation on read port ? ? ? ? ? partial reset, clears data in single queue ? ? ? ? ? expansion of up to 8 multi-queue devices in parallel is available ? ? ? ? ? jtag functionality (boundary scan) ? ? ? ? ? available in a 256-pin pbga, 1mm pitch, 17mm x 17mm ? ? ? ? ? high performance submicron cmos technology ? ? ? ? ? industrial temperature range (-40c to +85c) is available q 0 q 1 q 2 q 15 multi-queue flow-control device fstr wen paf ff wradd waden wclk paf n x9, x18 data in estr ren pae rdadd raden rclk pae n x9, x18 data out oe ov write control d in q out 8 8 8 7 read control write flags read flags 5939 drw01 functional block diagram
2 commercial and industrial temperature ranges idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits description: the idt72v51433/72v51443/72v51453 multi-queue flow-control de- vices are single chip within which anywhere between 1 and 16 discrete fifo queues can be setup. all queues within the device have a common data input bus, (write port) and a common data output bus, (read port). data written into the write port is directed to a respective queue via an internal de-multiplex operation, addressed by the user. data read from the read port is accessed from a respective queue via an internal multiplex operation, addressed by the user. data writes and reads can be performed at high speeds up to 166mhz, with access times of 3.7ns. data write and read operations are totally independent of each other, a queue maybe selected on the write port and a different queue on the read port or both ports may select the same queue simultaneously. the device provides full flag and output valid flag status for the queue selected for write and read operations respectively. also a programmable almost full and programmable almost empty flag for each queue is provided. two 8 bit programmable flag busses are available, providing status of queues not selected for write or read operations. when 8 or less queues are configured in the device these flag busses provide an individual flag per queue, when more than 8 queues are used, either a polled or direct mode of bus operation provides the flag busses with all queues status. bus matching is available on this device, either port can be 9 bits or 18 bits wide. when bus matching is used the device ensures the logical transfer of data throughput in a little endian manner. the user has full flexibility configuring queues within the device, being able to program the total number of queues between 1 and 16, the individual queue depths being independent of each other. the programmable flag positions are also user programmable. all programming is done via a dedicated serial port. if the user does not wish to program the multi-queue device, a default option is available that configures the device in a predetermined manner. both master reset and partial reset pins are provided on this device. a master reset latches in all configuration setup pins and must be performed before programming of the device can take place. a partial reset will reset the read and write pointers of an individual queue, provided that the queue is selected on both the write port and read port at the time of partial reset. a jtag test port is provided, here the multi-queue flow-control device has a fully functional boundary scan feature, compliant with ieee 1149.1 standard test access port and boundary scan architecture. see figure 1, multi-queue flow-control device block diagram for an outline of the functional blocks within the device.
3 idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits commercial and industrial temperature ranges oe x9, x18 q out output register q 0 - q 17 wradd waden input demux wclk wen write control logic d in write pointers active q flags paf general flag monitor fstr paf n ff fsync paf reset logic serial multi-queue programming pae / paf offset tms tdi tdo tck trst fm iw ow prs mrs si so sclk seni rclk ren read control logic read pointers active q flags pae general flag monitor estr ov esync rdadd raden df fxo fxi exi exo 5939 drw02 x9, x18 7 8 8 id0 id1 id2 device id 3 bit jtag logic seno dfm mast pae upto 16 fifo queues 0.5 mbit 1.1 mbit 2.3 mbit dual port memory output mux d 0 - d 17 pae n 8 figure 1. multi-queue flow-control device block diagram
4 commercial and industrial temperature ranges idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits d14 a d13 d12 d10 q9 d7 q6 d4 q3 d1 id1 tck tdo q12 q14 q15 d15 b d16 d11 d9 q8 d6 q5 d3 q2 d0 id0 tms tdi q11 q13 dnc d17 c gnd gnd d8 q7 d5 q4 d2 q1 trst q0 gnd id2 q10 q17 dnc gnd d gnd gnd vcc vcc vcc vcc vcc vcc vcc vcc vcc vcc q16 dnc dnc gnd e gnd gnd vcc vcc vcc vcc vcc vcc vcc vcc gnd gnd dnc dnc dnc gnd f gnd gnd vcc vcc vcc vcc gnd gnd gnd gnd gnd gnd dnc dnc dnc gnd g gnd gnd vcc vcc vcc vcc gnd gnd gnd gnd gnd gnd dnc dnc dnc gnd h gnd gnd vcc vcc gnd gnd gnd gnd gnd gnd gnd gnd dnc dnc dnc gnd j gnd gnd vcc vcc gnd gnd gnd gnd gnd gnd gnd gnd gnd dnc dnc gnd k gnd gnd vcc vcc vcc vcc gnd gnd gnd gnd gnd gnd gnd mast fm si l dfm df vcc vcc vcc vcc gnd gnd gnd gnd gnd gnd gnd iw ow seno m seni so vcc vcc vcc vcc vcc vcc vcc vcc gnd gnd oe rdadd0 rdadd1 wradd1 n wradd0 sclk vcc vcc vcc vcc vcc vcc vcc vcc vcc vcc rdadd2 p wradd2 waden pae 3 paf 3 pae 6 paf 6 pae 7 paf 7 pae ff ov r fsync fstr pae 2 paf 2 pae 5 paf 5 dnc paf 4 dnc paf dnc raden estr esync t fxi fxo paf 0 pae 1 paf 1 pae 4 wen ren wclk rclk prs mrs pae 0 12 3 4 13 512 611 710 8 9 14 15 16 5939 drw03 a1 ball pad corner exo exi wradd5 wradd4 wradd6 rdadd6 rdadd7 rdadd5 gnd wradd3 rdadd3 rdadd4 pin configuration pbga (bb256-1, order code: bb) top view note: 1. dnc - do not connect.
5 idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits commercial and industrial temperature ranges detailed description multi-queue structure the idt multi-queue flow-control device has a single data input port and single data output port with up to 16 fifo queues in parallel buffering between the two ports. the user can setup between 1 and 16 queues within the device. these queues can be configured to utilize the total available memory, providing the user with full flexibility and ability to configure the queues to be various depths, independent of one another. memory organization/ allocation the memory is organized into what is known as ?blocks?, each block being 512 x 18 or 1,024 x 9 bits. when the user is configuring the number of queues and individual queue sizes the user must allocate the memory to respective queues, in units of blocks, that is, a single queue can be made up from 0 to m blocks, where m is the total number of blocks available within a device. also the total size of any given queue must be in increments of 512 x 18 or 1,024 x 9. for the idt72v51433, idt72v51443 and idt72v51453 the total available memory is 64, 128 and 256 blocks respectively (a block being 512 x 18 or 1,024 x 9). if any port is configured for x18 bus width, a block size is 512 x 18. if both the write and read ports are configured for x9 bus width, a block size is 1,024 x 9. queues can be built from these blocks to make any size queue desired and any number of queues desired. bus widths the input port is common to all queues within the device, as is the output port. the device provides the user with bus matching options such that the input port and output port can be either x9 or x18 bits wide, the read and write port widths being set independently of one another. because the ports are common to all queues the width of the queues is not individually set, so that the input width of all queues are equal and the output width of all queues are equal. writing to & reading from the multi-queue data being written into the device via the input port is directed to a discrete queue via the write queue select address inputs. conversely, data being read from the device read port is read from a queue selected via the read queue select address inputs. data can be simultaneously written into and read from the same queue or different queues. once a queue is selected for data writes or reads, the writing and reading operation is performed in the same manner as a conventional idt synchronous fifo, utilizing clocks and enables, there is a single clock and enable per port. when a specific queue is addressed on the write port, data placed on the data inputs is written to that queue sequentially based on the rising edge of a write clock provided setup and hold times are met. conversely, data is read on to the output port after an access time from a rising edge on a read clock. the operation of the write port is comparable to the function of a conventional fifo operating in standard idt mode. write operations can be performed on the write port provided that the queue currently selected is not full, a full flag output provides status of the selected queue. the operation of the read port is comparable to the function of a conventional fifo operating in fwft mode. when a queue is selected on the output port, the next word in that queue will automatically fall through to the output register. all subsequent words from that queue require an enabled read cycle. data cannot be read from a selected queue if that queue is empty, the read port provides an output valid flag indicating when data read out is valid. if the user switches to a queue that is empty, the last word from the previous queue will remain on the output register. as mentioned, the write port has a full flag, providing full status of the selected queue. along with the full flag a dedicated almost full flag is provided, this almost full flag is similar to the almost full flag of a conventional idt fifo. the device provides a user programmable almost full flag for all 16 queues and when a respective queue is selected on the write port, the almost full flag provides status for that queue. conversely, the read port has an output valid flag, providing status of the data being read from the queue selected on the read port. as well as the output valid flag the device provides a dedicated almost empty flag. this almost empty flag is similar to the almost empty flag of a conventional idt fifo. the device provides a user programmable almost empty flag for all 16 queues and when a respective queue is selected on the read port, the almost empty flag provides status for that queue. programmable flag busses in addition to these dedicated flags, full & almost full on the write port and output valid & almost empty on the read port, there are two flag status busses. an almost full flag status bus is provided, this bus is 8 bits wide. also, an almost empty flag status bus is provided, again this bus is 8 bits wide. the purpose of these flag busses is to provide the user with a means by which to monitor the data levels within queues that may not be selected on the write or read port. as mentioned, the device provides almost full and almost empty registers (programmable by the user) for each of the 16 queues in the device. in the idt72v51433/72v51443/72v51453 multi-queue flow-control de- vices the user has the option of utilizing anywhere between 1 and 16 queues, therefore the 8 bit flag status busses are multiplexed between the 16 queues, a flag bus can only provide status for 8 of the 16 queues at any moment, this is referred to as a ?sector?, such that when the bus is providing status of queues 1 through 8, this is sector 1, when it is queues 9 through 16, this is sector 2. if less than 16 queues are setup in the device, there are still 2 sectors, such that in ?polled? mode of operation the flag bus will still cycle through 2 sectors. if for example only 14 queues are setup, sector 1 will reflect status of queues 1 through 8. sector 2 will reflect the status of queues 9 through 14 on the least significant 6 bits, the most significant 2 bits of the flag bus are don?t care. the flag busses are available in two user selectable modes of operation, ?polled? or ?direct?. when operating in polled mode a flag bus provides status of each sector sequentially, that is, on each rising edge of a clock the flag bus is updated to show the status of each sector in order. the rising edge of the write clock will update the almost full bus and a rising edge on the read clock will update the almost empty bus. the mode of operation is always the same for both the almost full and almost empty flag busses. when operating in direct mode, the sector on the flag bus is selected by the user. so the user can actually address the sector to be placed on the flag status busses, these flag busses operate independently of one another. addressing of the almost full flag bus is done via the write port and addressing of the almost empty flag bus is done via the read port. expansion expansion of multi-queue devices is also possible, up to 8 devices can be connected in a parallel fashion providing the possibility of both depth expansion or queue expansion. depth expansion means expanding the depths of individual queues. queue expansion means increasing the total number of queues available. depth expansion is possible by virtue of the fact that more memory blocks within a multi-queue device can be allocated to increase the depth of a queue. for example, depth expansion of 8 devices provides the possibility of 8 queues of 32k x 18 deep within the idt72v51433, 64k x 18 deep within the idt72v51443, and 128k x 18 deep within the idt72v51453, each
6 commercial and industrial temperature ranges idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits queue being setup within a single device utilizing all memory blocks available to produce a single queue. this is the deepest queue that can setup within a device. for queue expansion a maximum number of 128 (8 x 16) queues may be setup. if less queues are setup, then more memory blocks will be available to increase queue depths if desired. when connecting multi-queue devices in expansion mode all respective input pins (data & control) and output pins (data & flags), should be ?connected? together between individual devices.
7 idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits commercial and industrial temperature ranges d[17:0] data input bus lvttl these are the 18 data input pins. data is written into the device via these input pins on the rising edge din input of wclk provided that wen is low. due to bus matching not all inputs may be used, any unused inputs should be tied low. df (1) default flag lvttl if the user requires default programming of the multi-queue device, this pin must be setup before master input reset and must not toggle during any device operation. the state of this input at master reset determines the value of the pae / paf flag offsets. if df is low the value is 8, if df is high the value is 128. dfm (1) default mode lvttl the multi-queue device requires programming after master reset. the user can do this serially via the input serial port, or the user can use the default method. if dfm is low at master reset then serial mode will be selected, if high then default mode is selected. estr pae n flag bus lvttl if direct operation of the pae n bus has been selected, the estr input is used in conjunction with rclk strobe input and the rdadd bus to select a sector of queues to be placed on to the pae n bus outputs. a sector addressed via the rdadd bus is selected on the rising edge of rclk provided that estr is high. if polled operations has been selected, estr should be tied inactive, low. note, that a pae n flag bus selection cannot be made, (estr must not go active) until programming of the part has been completed and seno has gone low. esync pae n bus sync lvttl esync is an output from the multi-queue device that provides a synchronizing pulse for the pae n bus output during polled operation of the pae n bus. during polled operation each sector of queue status flags is loaded on to the pae n bus outputs sequentially based on rclk. the first rclk rising edge loads sector 1 on to pae n, the second rclk rising edge loads sector 2. the third rclk rising edge will again load sector 1. during the rclk cycle that sector 1 of a selected device is placed on to the pae n bus, the esync output will be high. for sector 2 of that device, the esync output will be low. exi pae n bus lvttl the exi input is used when multi-queue devices are connected in expansion mode and polled pae n expansion in input bus operation has been selected . exi of device ?n? connects directly to exo of device ?n-1?. the exi receives a token from the previous device in a chain. in single device mode the exi input must be tied low if the pae n bus is operated in direct mode. if the pae n bus is operated in polled mode the exi input must be connected to the exo output of the same device. in expansion mode the exi of the first device should be tied low, when direct mode is selected. exo pae n bus lvttl exo is an output that is used when multi-queue devices are connected in expansion mode and polled expansion out output pae n bus operation has been selected. exo of device ?n? connects directly to exi of device ?n+1?. this pin pulses when device n has placed its 2nd sector on to the pae n bus with respect to rclk. this pulse (token) is then passed on to the next device in the chain ?n+1? and on the next rclk rising edge the first sector of device n+1 will be loaded on to the pae n bus. this continues through the chain and exo of the last device is then looped back to exi of the first device. the esync output of each device in the chain provides synchronization to the user of this looping event. ff full flag lvttl this pin provides the full flag output for the active queue, that is, the queue selected on the input port for output write operations, (selected via wclk, wradd bus and waden). on the wclk cycle after a queue selection, this flag will show the status of the newly selected queue. data can be written to this queue on the next cycle provided ff is high. this flag has high-impedance capability, this is important during expansion of devices, when the ff flag output of up to 8 devices may be connected together on a common line. the device with a queue selected takes control of the ff bus, all other devices place their ff output into high-impedance. when a queue selection is made on the write port this output will switch from high-impedance control on the next wclk cycle. this flag is synchronized to wclk. fm (1) flag mode lvttl this pin is setup before a master reset and must not toggle during any device operation. the state of the input fm pin during master reset will determine whether the paf n and pae n flag busses operate in either polled or direct mode. if this pin is high the mode is polled, if low then it will be direct. fstr paf n flag bus lvttl if direct operation of the paf n bus has been selected, the fstr input is used in conjunction with wclk strobe input and the wradd bus to select a sector of queues to be placed on to the paf n bus outputs. a sector addressed via the wradd bus is selected on the rising edge of wclk provided that fstr is high. if polled operations has been selected, fstr should be tied inactive, low. note, that a paf n flag bus selection cannot be made, (fstr must not go active) until programming of the part has been completed and seno has gone low. pin descriptions symbol name i/o type description
8 commercial and industrial temperature ranges idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits pin descriptions (continued) fsync paf n bus sync lvttl fsync is an output from the multi-queue device that provides a synchronizing pulse for the paf n bus output during polled operation of the paf n bus. during polled operation each sector of queue status flags is loaded on to the paf n bus outputs sequentially based on wclk. the first wclk rising edge loads sector 1 on to paf n, the second wclk rising edge loads sector 2. the third wclk rising edge will again load sector 1. during the wclk cycle that sector 1 of a selected device is placed on to the paf n bus, the fsync output will be high. for sector 2 of that device, the fsync output will be low. fxi paf n bus lvttl the fxi input is used when multi-queue devices are connected in expansion mode and polled paf n expansion in input bus operation has been selected. fxi of device ?n? connects directly to fxo of device ?n-1?. the fxi receives a token from the previous device in a chain. in single device mode the fxi input must be tied low if the paf n bus is operated in direct mode. if the paf n bus is operated in polled mode the fxi input must be connected to the fxo output of the same device. in expansion mode the fxi of the first device should be tied low, when direct mode is selected. fxo paf n bus lvttl fxo is an output that is used when multi-queue devices are connected in expansion mode and polled expansion out output paf n bus operation has been selected . fxo of device ?n? connects directly to fxi of device ?n+1?. this pin pulses when device n has placed its 2nd sector on to the paf n bus with respect to wclk. this pulse (token) is then passed on to the next device in the chain ?n+1? and on the next wclk rising edge the first sector of device n+1 will be loaded on to the paf n bus. this continues through the chain and fxo of the last device is then looped back to fxi of the first device. the fsync output of each device in the chain provides synchronization to the user of this looping event. id[2:0] (1) device id pins lvttl for the 16q multi-queue device the wradd and rdadd address busses are 8 bits wide. when a queue input selection takes place the 3 msb?s of this 8 bit address bus are used to address the specific device (the 5 lsb?s are used to address the queue within that device). during write/read operations the 3 msb?s of the address are compared to the device id pins. the first device in a chain of multi-queue?s (connected in expansion mode), may be setup as ?000?, the second as ?001? and so on through to device 8 which is ?111?, however the id does not have to match the device order. in single device mode these pins should be setup as ?000? and the 3 msb?s of the wradd and rdadd address busses should be tied low. the id[2:0] inputs setup a respective devices id during master reset. these id pins must not toggle during any device operation. note, the device selected as the ?master? does not have to have the id of ?000?. iw (1) input width lvttl iw selects the bus width for the data input bus. if iw is low during a master reset then the bus width input is x18, if high then it is x9. mast (1) master device lvttl the state of this input at master reset determines whether a given device (within a chain of devices), is the input master device or a slave. if this pin is high, the device is the master if it is low then it is a slave. the master device is the first to take control of all outputs after a master reset, all slave devices go to high-impedance, preventing bus contention. if a multi-queue device is being used in single device mode, this pin must be set high. mrs master reset lvttl a master reset is performed by taking mrs from high to low, to high. device programming is required input after master reset. oe output enable lvttl the output enable signal is an asynchronous signal used to provide three-state control of the multi-queue input data output bus, qout. if a device has been configured as a ?master? device, the qout data outputs will be in a low impedance condition if the oe input is low. if oe is high then the qout data outputs will be in high impedance. if a device is configured a ?slave? device, then the qout data outputs will always be in high impedance until that device has been selected on the read port, at which point oe provides three- state of that respective device. ov output valid flag lvttl this output flag provides output valid status for the data word present on the multi-queue flow-control device output data output port, qout. this flag is therefore, 2-stage delayed to match the data output path delay. that is, there is a 2 rclk cycle delay from the time a given queue is selected for reads, to the time the ov flag represents the data in that respective queue. when a selected queue on the read port is read to empty, the ov flag will go high, indicating that data on the output bus is not valid. the ov flag also has high- impedance capability, required when multiple devices are used and the ov flags are tied together. ow (1) output width lvttl ow selects the bus width for the data output bus. if ow is low during a master reset then the bus width input is x18, if high then it is x9. symbol name i/o type description
9 idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits commercial and industrial temperature ranges pae programmable lvttl this pin provides the almost-empty flag status for the queue that has been selected on the output port almost-empty flag output for read operations, (selected via rclk, rdadd and raden). this pin is low when the selected queue is almost-empty. this flag output may be duplicated on one of the pae n bus lines. this flag is synchronized to rclk. pae n programmable lvttl on the 16q device the pae n bus is 8 bits wide. this output bus provides pae status of 8 queues (1 sector), almost-empty flag bus output within a selected device, having a total of 2 sectors. during queue read/write operations these outputs provide programmable empty flag status, in either direct or polled mode. the mode of flag operation is determined during master reset via the state of the fm input. this flag bus is capable of high-impedance state, this is important during expansion of multi-queue devices. during direct operation the pae n bus is updated to show the pae status of a sector of queues within a selected device. selection is made using rclk, estr and rdadd. during polled operation the pae n bus is loaded with the pae status of multi-queue flow-control sectors sequentially based on the rising edge of rclk. paf programmable lvttl this pin provides the almost-full flag status for the queue that has been selected on the input port for write almost-full flag output operations, (selected via wclk, wradd and waden). this pin is low when the selected queue is almost-full. this flag output may be duplicated on one of the paf n bus lines. this flag is synchronized to wclk. paf n programmable lvttl on the 16q device the paf n bus is 8 bits wide. at any one time this output bus provides paf status of almost-full flag bus output 8 queues (1 sector), within a selected device, having a total of 2 sectors. during queue read/write operations these outputs provide programmable full flag status, in either direct or polled mode. the mode of flag operation is determined during master reset via the state of the fm input. this flag bus is capable of high-impedance state, this is important during expansion of multi-queue devices. during direct operation the paf n bus is updated to show the paf status of a sector of queues within a selected device. selection is made using wclk, fstr, wradd and waden. during polled operation the paf n bus is loaded with the paf status of multi-queue flow-control sectors sequentially based on the rising edge of wclk. prs partial reset lvttl a partial reset can be performed on a single queue selected within the multi-queue device. before a partial input reset can be performed on a queue, that queue must be selected on both the write port and read port 2 clock cycles before the reset is performed. a partial reset is then performed by taking prs low for one wclk cycle and one rclk cycle. the partial reset will only reset the read and write pointers to the first memory location, none of the devices configuration will be changed. q[17:0] data output bus lvttl these are the 18 data output pins. data is read out of the device via these output pins on the rising edge qout output of rclk provided that ren is low, oe is low and the queue is selected. due to bus matching not all outputs may be used, any unused outputs should not be connected. raden read address enable lvttl the raden input is used in conjunction with rclk and the rdadd address bus to select a queue to input be read from. a queue addressed via the rdadd bus is selected on the rising edge of rclk provided that raden is high. raden should be asserted (high) only during a queue change cycle(s). raden should not be permanently tied high. raden cannot be high for the same rclk cycle as estr. note, that a read queue selection cannot be made, (raden must not go active) until programming of the part has been completed and seno has gone low. rclk read clock lvttl when enabled by ren , the rising edge of rclk reads data from the selected queue via the output input bus qout. the queue to be read is selected via the rdadd address bus and a rising edge of rclk while raden is high. a rising edge of rclk in conjunction with estr and rdadd will also select the pae n flag sector to be placed on the pae n bus during direct flag operation. during polled flag operation the pae n bus is cycled with respect to rclk and the esync signal is synchronized to rclk. the pae and ov outputs are all synchronized to rclk. during device expansion the exo and exi signals are based on rclk. rclk must be continuous and free-running. rdadd read address bus lvttl for the 16q device the rdadd bus is 8 bits. the rdadd bus is a dual purpose address bus. the first [7:0] input function of rdadd is to select a queue to be read from. the least significant 4 bits of the bus, rdadd[3:0] are used to address 1 of 16 possible queues within a multi-queue device. address pin, rdadd[4] provides the user with a null-q address. if the user does not wish to address one of the 16 queues, a null-q can be addressed using this pin. the null-q operation is discussed in more detail later. the most significant 3 bits, rdadd[7:5] are used to select 1 of 8 possible multi-queue devices that may be connected in expansion mode. these 3 msb?s will address a device with the matching id code. the address present on the rdadd bus will be selected on a rising edge of rclk provided that raden is high, (note, that pin descriptions (continued) symbol name i/o type description
10 commercial and industrial temperature ranges idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits pin descriptions (continued) symbol name i/o type description rdadd read address bus lvttl data can be p laced on to the qout bus, read from the previously selected queue on this rclk edge). on [7:0] input the next rising rclk edge after a read queue select, a data word from the previous queue will be placed (continued) onto the outputs, qout, regardless of the ren input. two rclk rising edges after read queue select, data will be placed on to the qout outputs from the newly selected queue, regardless of ren due to the first word fall through effect. the second function of the rdadd bus is to select the sector of queues to be loaded on to the pae n bus during strobed flag mode. the least significant bit, rdadd[0] is used to select the sector of a device to be placed on the pae n bus. the most significant 3 bits, rdadd[7:5] are again used to select 1 of 8 possible multi-queue devices that may be connected in expansion mode. address bits rdadd[4:2] are don?t care during sector selection. the sector address present on the rdadd bus will be selected on the rising edge of rclk provided that estr is high, (note, that data can be placed on to the qout bus, read from the previously selected queue on this rclk edge). please refer to table 2 for details on rdadd bus. ren read enable lvttl the ren input enables read operations from a selected queue based on a rising edge of rclk. a input queue to be read from can be selected via rclk, raden and the rdadd address bus regardless of the state of ren . data from a newly selected queue will be available on the qout output bus on the second rclk cycle after queue selection regardless of ren due to the fwft operation. a read enable is not required to cycle the pae n bus (in polled mode) or to select the pae n sector , (in direct mode). sclk serial clock lvttl if serial programming of the multi-queue device has been selected during master reset, the sclk input input clocks the serial data through the multi-queue device. data setup on the si input is loaded into the device on the rising edge of sclk provided that seni is enabled, low. when expansion of devices is performed the sclk of all devices should be connected to the same source. seni serial input enable lvttl during serial programming of a multi-queue device, data loaded onto the si input will be clocked into t he input part (via a rising edge of sclk), provided the seni input of that device is low. if multiple devices are cascaded, the seni input should be connected to the seno output of the previous device. so when serial loading of a given device is complete, its seno output goes low, allowing the next device in the chain to be programmed ( seno will follow seni of a given device once that device is programmed). the seni input of the master device (or single device), should be controlled by the user. seno serial output enable lvttl this output is used to indicate that serial programming or default programming of the multi-queue device output has been completed. seno follows seni once programming of a device is complete. therefore, seno will go low after programming provided seni is low, once seni is taken high again, seno will also go high. when the seno output goes low, the device is ready to begin normal read/write operations. if multiple devices are cascaded and serial programming of the devices will be used, the seno output should be connected to the seni input of the next device in the chain. when serial programming of the first device is complete, seno will go low, thereby taking the seni input of the next device low and so on throughout the chain. when a given device in the chain is fully programmed the seno output essentially follows the seni input. the user should monitor the seno output of the final device in the chain. when this output goes low, serial loading of all devices has been completed. si serial in lvttl during serial programming this pin is loaded with the serial data that will configure the multi-queue devices. input data present on si will be loaded on a rising edge of sclk provided that seni is low. in expansion mode the serial data input is loaded into the first device in a chain. when that device is loaded and its seno has gone low, the data present on si will be directly output to the so output. the so pin of the first device connects to the si pin of the second and so on. the multi-queue device setup registers are shift registers. so serial out lvttl this output is used in expansion mode and allows serial data to be passed through devices in the chain output to complete programming of all devices. the si of a device connects to so of the previous device in the chain. the so of the final device in a chain should not be connected. tck (2) jtag clock lvttl clock input for jtag function. one of four terminals required by ieee standard 1149.1-1990. test input operations of the device are synchronous to tck. data from tms and tdi are sampled on the rising edge of tck and outputs change on the falling edge of tck. if the jtag function is not used this signal needs to be tied to gnd. tdi (2) jtag test data lvttl one of four terminals required by ieee standard 1149.1-1990. during the jtag boundary scan input input operation, test data serially loaded via the tdi on the rising edge of tck to either the instruction register, id register and bypass register. an internal pull-up resistor forces tdi high if left unconnected.
11 idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits commercial and industrial temperature ranges pin descriptions (continued) notes: 1. inputs should not change after master reset. 2. these pins are for the jtag port. please refer to pages 45-49 and figures 29-31. symbol name i/o type description tdo (2) jtag test data lvttl one of four terminals required by ieee standard 1149.1-1990. during the jtag boundary scan output output operation, test data serially loaded output via the tdo on the falling edge of tck from either the instruction register, id register and bypass register. this output is high impedance except when shifting, while in shift-dr and shift-ir controller states. tms (2) jtag mode select lvttl tms is a serial input pin. one of four terminals required by ieee standard 1149.1-1990. tms directs the input device through its tap controller states. an internal pull-up resistor forces tms high if left unconnected. trst (2) jtag reset lvttl trst is an asynchronous reset pin for the jtag controller. the jtag tap controller does not automatically input reset upon power-up, thus it must be reset by either this signal or by setting tms= high for five tck cycles. if the tap controller is not properly reset then the outputs will always be in high-impedance. if the jtag function is used but the user does not want to use trst , then trst can be tied with mrs to ensure proper queue operation. if the jtag function is not used then this signal needs to be tied to gnd. an internal pull-up resistor forces trst high if left unconnected. waden write address enable lvttl the waden input is used in conjunction with wclk and the wradd address bus to select a queue to input be written in to. a queue addressed via the wradd bus is selected on the rising edge of wclk provided that waden is high. waden should be asserted (high) only during a queue change cycle(s). waden should not be permanently tied high. waden cannot be high for the same wclk cycle as fstr. note, that a write queue selection cannot be made, (waden must not go active) until programming of the part has been completed and seno has gone low. wclk write clock lvttl when enabled by wen , the rising edge of wclk writes data into the selected queue via the input bus, input din. the queue to be written to is selected via the wradd address bus and a rising edge of wclk while waden is high. a rising edge of wclk in conjunction with fstr and wradd will also select the flag sector to be placed on the paf n bus during direct flag operation. during polled flag operation the paf n bus is cycled with respect to wclk and the fsync signal is synchronized to wclk. the paf n, paf and ff outputs are all synchronized to wclk. during device expansion the fxo and fxi signals are based on wclk. the wclk must be continuous and free-running. wen write enable lvttl the wen input enables write operations to a selected queue based on a rising edge of wclk. a queue input to be written to can be selected via wclk, waden and the wradd address bus regardless of the state of wen . data present on din can be written to a newly selected queue on the second wclk cycle after queue selection provided that wen is low. a write enable is not required to cycle the paf n bus (in polled mode) or to select the paf n sector , (in direct mode). wradd write address bus lvttl for the 16q device the wradd bus is 7 bits. the wradd bus is a dual purpose address bus. the first [6:0] input function of wradd is to select a queue to be written to. the least significant 4 bits of the bus, wradd[3:0] are used to address 1 of 16 possible queues within a multi-queue device. the most significant 3 bits, wradd[6:4] are used to select 1 of 8 possible multi-queue devices that may be connected in expansion mode. these 3 msb?s will address a device with the matching id code. the address present on the wradd bus will be selected on a rising edge of wclk provided that waden is high, (note, that data present on the din bus can be written into the previously selected queue on this wclk edge and on the next rising wclk also, providing that wen is low). two wclk rising edges after write queue select, data can be written into the newly selected queue. the second function of the wradd bus is to select the sector of queues to be loaded on to the paf n bus during strobed flag mode. the least significant bit, wradd[0] is used to select the sector of a device to be placed on the paf n bus. the most significant 3 bits, wradd[6:4] are again used to select 1 of 8 possible multi-queue devices that may be connected in expansion mode. address bits wradd[3:1] are don?t care during sector selection. the sector address present on the wradd bus will be selected on the rising edge of wclk provided that fstr is high, (note, that data can be written into the previously selected queue on this wclk edge). please refer to table 1 for details on the wradd bus. v cc +3.3v supply power these are v cc power supply pins and must all be connected to a +3.3v supply rail. gnd ground pin ground these are ground pins and must all be connected to the gnd supply rail.
12 commercial and industrial temperature ranges idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits symbol rating com'l & ind'l unit v term terminal voltage ?0.5 to +4.5 v with respect to gnd t stg storage temperature ?55 to +125 c i out dc output current ?50 to +50 ma dc electrical characteristics (commercial: v cc = 3.3v 0.15v, t a = 0 c to +70 c;industrial: v cc = 3.3v 0.15v, t a = 40 c to +85 c; jedec jesd8-a compliant) symbol parameter min. max. unit i li (1) input leakage current ?10 10 a i lo (2) output leakage current ?10 10 a v oh output logic ?1? voltage, i oh = ?8 ma 2.4 ? v v ol output logic ?0? voltage, i ol = 8 ma ? 0.4 v i cc1 (3,4,5) active power supply current ? 100 ma i cc2 (3,6) standby current ? 25 ma absolute maximum ratings recommended dc operating conditions notes : 1. measurements with 0.4 v in v cc . 2. oe v ih, 0.4 v out v cc. 3. tested with outputs open (i out = 0). 4. rclk and wclk toggle at 20 mhz and data inputs switch at 10 mhz. 5. typical i cc1 = 16 + 3.14*f s + 0.02*c l *f s (in ma) with v cc = 3.3v, t a = 25 c, f s = wclk frequency = rclk frequency (in mhz, using ttl levels), data switching at f s /2, c l = capacitive load (in pf). 6. rclk and wclk, toggle at 20 mhz. the following inputs should be pulled to gnd: wradd, rdadd, waden, raden, fstr, estr, sclk, si, exi, fxi and all data inputs. the following inputs should be pulled to v cc : wen , ren , seni , prs , mrs , tdi, tms and trst . all other inputs are don't care, and should be pulled high or low. note: 1. stresses greater than those listed under absolute maximum ratings may cause permanent damage to the device. this is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. exposure to absolute maximum rating conditions for extended periods may affect reliability. note: 1. v cc = 3.3v 0.15v, jedec jesd8-a compliant. notes: 1. with output deselected, ( oe v ih ). 2. characterized values, not currently tested. capacitance (t a = +25 c, f = 1.0mhz) symbol parameter (1) conditions max. unit c in (2) input v in = 0v 10 pf capacitance c out (1,2) output v out = 0v 10 pf capacitance symbol parameter min. typ. max. unit v cc (1) supply voltage (com'l/ind'l) 3.15 3.3 3.45 v gnd supply voltage (com'l/ind'l) 0 0 0 v v ih input high voltage (com'l/ind'l) 2.0 ? v cc +0.3 v v il input low voltage (com'l/ind'l) ? ? 0.8 v t a operating temperature commercial 0 ? +70 c t a operating temperature industrial -40 ? +85 c
13 idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits commercial and industrial temperature ranges input pulse levels gnd to 3.0v input rise/fall times 1.5ns input timing reference levels 1.5v output reference levels 1.5v output load see figure 2a & 2b ac test conditions figure 2a. ac test load figure 2b. lumped capacitive load, typical derating 5939 drw04 50 ? v cc /2 i/o z 0 = 50 ? 5939 drw04a 6 5 4 3 2 1 20 30 50 80 100 200 ca p acitance (p f ) t cd (typical, ns) output enable & disable timing ac test loads v ih oe v il t oe & t olz 100mv 100mv t ohz 100mv 100mv output normally low output normally high v ol v oh v cc /2 5939 drw04b output enable output disable v cc /2 v cc /2 v cc /2
14 commercial and industrial temperature ranges idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits ac electrical characteristics (commercial: v cc = 3.3v 0.15v, t a = 0 c to +70 c;industrial: v cc = 3.3v 0.15v, t a = 40 c to +85 c; jedec jesd8-a compliant) commercial com'l & ind'l (1) idt72v51433l6 idt72v51433l7-5 idt72v51443l6 idt72v51443l7-5 idt72v51453l6 idt72v51453l7-5 symbol parameter min. max. min. max. unit f s clock cycle frequency (wclk & rclk) ? 166 ? 133 mhz t a data access time 0.6 3.7 0.6 4 ns t clk clock cycle time 6 ? 7.5 ? ns t clkh clock high time 2.7 ? 3.5 ? ns t clkl clock low time 2.7 ? 3.5 ? ns t ds data setup time 2 ? 2.0 ? ns t dh data hold time 0.5 ? 0.5 ? ns t ens enable setup time 2 ? 2.0 ? ns t enh enable hold time 0.5 ? 0.5 ? ns t rs reset pulse width 10 ? 10 ? ns t rss reset setup time 15 ? 15 ? ns t rsr reset recovery time 10 ? 10 ? ns t prss partial reset setup 2.0 ? 2.5 ? ns t prsh partial reset hold 0.5 ? 0.5 ? ns t olz ( oe - q n) (2) output enable to output in low-impedance 0.6 3.7 0.6 4 ns t ohz (2) output enable to output in high-impedance 0.6 3.7 0.6 4 ns t oe output enable to data output valid 0.6 3.7 0.6 4 ns f c clock cycle frequency (sclk) ? 10 ? 10 mhz t sclk serial clock cycle 100 ? 100 ? ns t sckh serial clock high 45 ? 45 ? ns t sckl serial clock low 45 ? 45 ? ns t sds serial data in setup 20 ? 20 ? ns t sdh serial data in hold 1.2 ? 1.2 ? ns t sens serial enable setup 20 ? 20 ? ns t senh serial enable hold 1.2 ? 1.2 ? ns t sdo sclk to serial data out ? 20 ? 20 ns t seno sclk to serial enable out ? 20 ? 20 ns t sdop serial data out propagation delay 1.5 3.7 1.5 4 ns t senop serial enable propagation delay 1.5 3.7 1.5 4 ns t pcwq programming complete to write queue selection 20 ? 20 ? ns t pcrq programming complete to read queue selection 20 ? 20 ? ns t as address setup 2.5 ? 3.0 ? ns t ah address hold 1 ? 1 ? ns t wff write clock to full flag ? 3.7 ? 5 ns t rov read clock to output valid ? 3.7 ? 5 ns t sts strobe setup 2 ? 2 ? ns t sth strobe hold 0.5 ? 0.5 ? ns t qs queue setup 2 ? 2.5 ? ns t qh queue hold 0.5 ? 0.5 ? ns t waf wclk to paf flag 0.6 3.7 0.6 4 ns t rae rclk to pae flag 0.6 3.7 0.6 4 ns t paf write clock to synchronous almost-full flag bus 0.6 3.7 0.6 4 ns t pae read clock to synchronous almost-empty flag bus 0.6 3.7 0.6 4 ns notes: 1. industrial temperature range product for the 7-5ns is available as a standard device. all other speed grades available by sp ecial order. 2. values guaranteed by design, not currently tested.
15 idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits commercial and industrial temperature ranges ac electrical characteristics (continued) (commercial: v cc = 3.3v 0.15v, t a = 0 c to +70 c;industrial: v cc = 3.3v 0.15v, t a = 40 c to +85 c; jedec jesd8-a compliant) t paelz (2) rclk to pae flag bus to low-impedance 0.6 3.7 0.6 4 ns t paehz (2) rclk to pae flag bus to high-impedance 0.6 3.7 0.6 4 ns t paflz (2) wclk to paf flag bus to low-impedance 0.6 3.7 0.6 4 ns t pafhz (2) wclk to paf flag bus to high-impedance 0.6 3.7 0.6 4 ns t ffhz (2) wclk to full flag to high-impedance 0.6 3.7 0.6 4 ns t fflz (2) wclk to full flag to low-impedance 0.6 3.7 0.6 4 ns t ovlz (2) rclk to output valid flag to low-impedance 0.6 3.7 0.6 4 ns t ovhz (2) rclk to output valid flag to high-impedance 0.6 3.7 0.6 4 ns t fsync wclk to paf bus sync to output 0.6 3.7 0.6 4 ns t fxo wclk to paf bus expansion to output 0.6 3.7 0.6 4 ns t esync rclk to pae bus sync to output 0.6 3.7 0.6 4 ns t exo rclk to pae bus expansion to output 0.6 3.7 0.6 4 ns t skew1 skew time between rclk and wclk for ff and ov 4.5 ? 5.75 ? ns t skew2 skew time between rclk and wclk for paf and pae 6 ? 7.5 ? ns t skew3 skew time between rclk and wclk for paf [0:7] and pae [0:7] 6 ? 7.5 ? ns t skew4 skew time between rclk and wclk for ov 6 ? 7.5 ? ns t xis expansion input setup 1.0 ? 1.3 ? ns t xih expansion input hold 0.5 ? 0.5 ? ns commercial com'l & ind'l (1) idt72v51433l6 idt72v51433l7-5 idt72v51443l6 idt72v51443l7-5 idt72v51453l6 idt72v51453l7-5 symbol parameter min. max. min. max. unit notes: 1. industrial temperature range product for the 7-5ns is available as a standard device. all other speed grades available by sp ecial order. 2. values guaranteed by design, not currently tested.
16 commercial and industrial temperature ranges idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits functional description master reset a master reset is performed by toggling the mrs input from high to low to high. during a master reset all internal multi-queue device setup and control registers are initialized and require programming either serially by the user via the serial port, or using the default settings. during a master reset the state of the following inputs determine the functionality of the part, these pins should be held high or low. fm ? flag bus mode iw, ow ? bus matching options mast ? master device id0, 1, 2 ? device id dfm ? programming mode, serial or default df ? offset value for pae and paf once a master reset has taken place, the device must be programmed either serially or via the default method before any read/write operations can begin. see figure 4, master reset for relevant timing. partial reset a partial reset is a means by which the user can reset both the read and write pointers of a single queue that has been setup within a multi-queue device. before a partial reset can take place on a queue, the respective queue must be selected on both the read port and write port a minimum of 2 rclk and 2 wclk cycles before the prs goes low. the partial reset is then performed by toggling the prs input from high to low to high, maintaining the low state for at least one wclk and one rclk cycle. once a partial reset has taken place a minimum of 3 wclk and 3 rclk cycles must occur before enabled writes or reads can occur. a partial reset only resets the read and write pointers of a given queue, a partial reset will not effect the overall configuration and setup of the multi-queue device and its queues. see figure 5, partial reset for relevant timing. serial programming the multi-queue flow-control device is a fully programmable device, provid- ing the user with flexibility in how queues are configured in terms of the number of queues, depth of each queue and position of the paf / pae flags within respective queues. all user programming is done via the serial port after a master reset has taken place. internally the multi-queue device has setup registers which must be serially loaded, these registers contain values for every queue within the device, such as the depth and pae / paf offset values. the idt72v51433/72v51443/72v51453 devices are capable of up to 16 queues and therefore contain 16 sets of registers for the setup of each queue. during a master reset if the dfm (default mode) input is low, then the device will require serial programming by the user. it is recommended that the user utilize a ?c? program provided by idt, this program will prompt the user for all information regarding the multi-queue setup. the program will then generate a serial bit stream which should be serially loaded into the device via the serial port. for the idt72v51433/72v51443/72v51453 devices the serial program- ming requires a total number of serially loaded bits per device, (sclk cycles with seni enabled), calculated by: 19+(qx72) where q is the number of queues the user wishes to setup within the device. please refer to the separate application note, an-303 for recommended control of the serial programming port. once the master reset is complete and mrs is high, the device can be serially loaded. data present on the si (serial in), input is loaded into the serial port on a rising edge of sclk (serial clock), provided that seni (serial in enable), is low. once serial programming of the device has been successfully completed the device will indicate this via the seno (serial output enable) going active, low. upon detection of completion of programming, the user should cease all programming and take seni inactive, high. note, seno follows seni once programming of a device is complete. therefore, seno will go low after programming provided seni is low, once seni is taken high again, seno will also go high. the operation of the so output is similar, when programming of a given device is complete, the so output will follow the si input. if devices are being used in expansion mode the serial ports of devices should be cascaded. the user can load all devices via the serial input port control pins, si & seni , of the first device in the chain. again, the user may utilize the ?c? program to generate the serial bit stream, the program prompting the user for the number of devices to be programmed. the seno and so (serial out) of the first device should be connected to the seni and si inputs of the second device respectively and so on, with the seno & so outputs connecting to the seni & si inputs of all devices through the chain. all devices in the chain should be connected to a common sclk. the serial output port of the final device should be monitored by the user. when seno of the final device goes low, this indicates that serial programming of all devices has been successfully com- pleted. upon detection of completion of programming, the user should cease all programming and take seni of the first device in the chain inactive, high. as mentioned, the first device in the chain has its serial input port controlled by the user, this is the first device to have its internal registers serially loaded by the serial bit stream. when programming of this device is complete it will take its seno output low and bypass the serial data loaded on the si input to its so output. the serial input of the second device in the chain is now loaded with the data from the so of the first device, while the second device has its seni input low. this process continues through the chain until all devices are programmed and the seno of the final device goes low. once all serial programming has been successfully completed, normal operations, (queue selections on the read and write ports) may begin. when connected in expansion mode, the idt72v51433/72v51443/72v51453 de- vices require a total number of serially loaded bits per device to complete serial programming, (sclk cycles with seni enabled), calculated by: n[19+(qx72)] where q is the number of queues the user wishes to setup within the device, where n is the number of devices in the chain. see figure 6, serial port connection and figure 7, serial programming for connection and timing information. default programming during a master reset if the dfm (default mode) input is high the multi- queue device will be configured for default programming, (serial programming is not permitted). default programming provides the user with a simpler, however limited means by which to setup the multi-queue flow-control device, rather than using the serial programming method. the default mode will configure a multi-queue device such that the maximum number of queues possible are setup, with all of the parts available memory blocks being allocated equally between the queues. the values of the pae / paf offsets is determined by the state of the df (default) pin during a master reset. for the idt72v51433/72v51443/72v51453 devices the default mode will setup 16 queues, each queue configured as follows: for the idt72v51433 with x9 input and x9 output ports, depth is 4,096, if one or both ports is x18, then the depth is 2,048. for the idt72v51443 with x9 input and x9 output ports, depth is 8,192, if one or both ports is x18, then the depth is 4,096. for the idt72v51453 with x9 input and x9 output ports, depth is 16,384, if one or both ports is x18, then the depth is 8,192. for both devices the value of the pae / paf offsets is determined at master reset by the state of the df input. if df is low then both the pae & paf offset will be 8, if high then the value is 128.
17 idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits commercial and industrial temperature ranges when configuring the idt72v51433/72v51443/72v51453 devices in de- fault mode the user simply has to apply wclk cycles after a master reset, until seno goes low, this signals that default programming is complete. these clock cycles are required for the device to load its internal setup registers. when a single multi-queue device is used, the completion of device programming is signaled by the seno output of a device going from high to low. note, that seni must be held low when a device is setup for default programming mode. when multi-queue devices are connected in expansion mode, the seni of the first device in a chain can be held low. the seno of a device should connect to the seni of the next device in the chain. the seno of the final device is used to indicate that default programming of all devices is complete. when the final seno goes low normal operations may begin. again, all devices will be programmed with their maximum number of queues and the memory divided equally between them. please refer to figure 8, default programming . write queue selection & write operation the idt72v51433/72v51443/72v51453 multi-queue flow-control devices have up to 16 queues that data can be written into via a common write port using the data inputs, din, write clock, wclk and write enable, wen . the queue address present on the write address bus, wradd during a rising edge on wclk while write address enable, waden is high, is the queue selected for write operations. the state of wen is don?t care during the write queue selection cycle. the queue selection only has to be made on a single wclk cycle, this will remain the selected queue until another queue is selected, the selected queue is always the last queue selected. the write port is designed such that 100% bus utilization can be obtained. this means that data can be written into the device on every wclk rising edge including the cycle that a new queue is being addressed. when a new queue is selected for write operations the address for that queue must be present on the wradd bus during a rising edge of wclk provided that waden is high. a queue to be written to need only be selected on a single rising edge of wclk. all subsequent writes will be written to that queue until a new queue is selected. a minimum of 2 wclk cycles must occur between queue selections on the write port. on the next wclk rising edge the write port discrete full flag will update to show the full status of the newly selected queue. on the second rising edge of wclk, data present on the data input bus, din can be written into the newly selected queue provided that wen is low and the new queue is not full. the cycle of the queue selection and the next cycle will continue to write data present on the data input bus, din into the previous queue provided that wen is active low. if wen is high, inactive for these 2 clock cycles, then data will not be written in to the previous queue. if the newly selected queue is full at the point of its selection, then writes to that queue will be prevented, a full queue cannot be written into. in the 16 queue multi-queue device the wradd address bus is 7 bits wide. the least significant 4 bits are used to address one of the 16 available queues within a single multi-queue device. the most significant 3 bits are used when a device is connected in expansion mode, up to 8 devices can be connected in expansion, each device having its own 3 bit address. the selected device is the one for which the address matches a 3 bit id code, which is statically setup on the id pins, id0, id1, and id2 of each individual device. note, the wradd bus is also used in conjunction with fstr (almost full flag bus strobe), to address the almost full flag bus sector during direct mode of operation. refer to table 1, for write address bus arrangement. also, refer to figure 9, write queue select, write operation and full flag operation and figure 11, full flag timing expansion mode for timing diagrams. table 1 write address bus, wradd[6:0] operation wclk waden fstr wradd[6:0] write queue select 10 01 device select (compared to id0,1,2) write queue address (4 bits = 16 queues) 654 32 10 765432 0 device select (compared to id0,1,2) x x x sector address paf n sector select q0 : q7 paf 0 : paf 7 sector address queue status on paf n bus 0 1 q8 : q15 paf 0 : paf 7 5939 drw05 1 x
18 commercial and industrial temperature ranges idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits read queue selection & read operation the multi-queue flow-control device has up to 16 queues that data is read from via a common read port using the data outputs, qout, read clock, rclk and read enable, ren . an output enable, oe control pin is also provided to allow high-impedance selection of the qout data outputs. the multi-queue device read port operates in a mode similar to ?first word fall through? on a traditional idt fifo, but with the added feature of data output pipelining. this data pipelining on the output port allows the user to achieve 100% bus utilization, which is the ability to read out a data word on every rising edge of rclk regardless of whether a new queue is being selected for read operations. the queue address present on the read address bus, rdadd during a rising edge on rclk while read address enable, raden is high, is the queue selected for read operations. a queue to be read from need only be selected on a single rising edge of rclk. all subsequent reads will be read from that queue until a new queue is selected. a minimum of 2 rclk cycles must occur between queue selections on the read port. data from the newly selected queue will be present on the qout outputs after 2 rclk cycles plus an access time, provided that oe is active, low. on the same rclk rising edge that the new queue is selected, data can still be read from the previously selected queue, provided that ren is low, active and the previous queue is not empty on the following rising edge of rclk a word will be read from the previously selected queue regardless of ren due to the fall through operation, (provided the queue is not empty). remember that oe allows the user to place the qout, data output bus into high-impedance and the data can be read onto the output register regardless of oe . when a queue is selected on the read port, the next word available in that queue (provided that the queue is not empty), will fall through to the output register after 2 rclk cycles. as mentioned, in the previous 2 rclk cycles to the new data being available, data can still be read from the previous queue, provided that the queue is not empty. at the point of queue selection, the 2-stage internal data pipeline is loaded with the last word from the previous queue and the next word from the new queue, both these words will fall through to the output register consecutively upon selection of the new queue. this pipelining effect provides the user with 100% bus utilization, but brings about the possibility that a ?null? queue may be required within a multi-queue device. null queue operation is discussed in the next section on. if an empty queue is selected for read operations on the rising edge of rclk, on the same rclk edge and the following rclk edge, 2 final reads will be made from the previous queue, provided that ren is active, low. on the next rclk rising edge a read from the new queue will not occur, because the queue is empty. the last word in the data output register (from the previous queue), will remain there, but the output valid flag, ov will go high, to indicate that the data present is no longer valid. the rdadd bus is also used in conjunction with estr (almost empty flag bus strobe), to address the almost empty flag bus of a respective device during direct mode of operation. in the 16 queue multi-queue device the rdadd address bus is 8 bits wide. the least significant 4 bits are used to address one of the 16 available queues within a single multi-queue device. the 5th least significant bit is used to select a "null" queue. during a null-q selection the 4 lsb's are don't care. the null-q is seen as an empty queue on the read port. null-q operation is discussed in more detail in a separate section. the most significant 3 bits are used when a device is connected in expansion mode, up to 8 devices can be connected in expansion, each device having its own 3 bit address. the selected device is the one for which the address matches a 3 bit id code, which is statically setup on the id pins, id0, id1, and id2 of each individual device. refer to table 2, for read address bus arrangement. also, refer to figures 12,14 & 15 for read queue selection and read port operation timing diagrams. operation r clk raden estr rdadd[7:0] read queue select 10 01 device select (compared to id0,1,2) read queue address (4 bits = 16 queues) 7 6 5 4 3210 4321 0 device select (compared to id0,1,2) x x x sector address pae n sector select q0 : q7 pae 0 : pae 7 sector address queue status on pae n bus 0 1 q8 : q15 pae 0 : pae 7 5939 drw06 x null-q select pin table 2 read address bus, rdadd[7:0]
19 idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits commercial and industrial temperature ranges null queue operation (of the read port) pipelining of data to the output port enables the device to provide 100% bus utilization in standard mode. data can be read out of the multi-queue flow-control device on every rclk cycle regardless of queue switches or other opera- tions. the device architecture is such that the pipeline is constantly filled with the next words in a selected queue to be read out, again providing 100% bus utilization. this type of architecture does assume that the user is constantly switching queues such that during a queue switch, the last data word required from the previous queue will fall through the pipeline to the output. note, that if reads cease at the empty boundary of a queue, then the last word will automatically flow through the pipeline to the output. the null-q is selected via read port address space rdadd[4]. the rdadd[7:0] bus should be addressed with xxx1xxxx, this address is the null-q. a null queue can be selected when no further reads are required from a previously selected queue. changing to a null queue will continue to propagate data in the pipeline to the previous queue?s output. the null-q can remain selected until a data becomes available in another queue for reading. the null-q can be utilized in either standard or packet mode. note: if the user switches the read port to the null queue, this queue is seen as and treated as an empty queue, therefore after switching to the null queue the last word from the previous queue will remain in the output register and the ov flag will go high, indicating data is not valid. the null queue operation only has significance to the read port of the multi- queue, it is a means to force data through the pipeline to the output. null-q selection and operation has no meaning on the write port of the device. also, refer to figure 16, read operation and null queue select for diagram. bus matching operation bus matching operation between the input port and output port is available. during a master reset of the multi-queue the state of the two setup pins, iw (input width) and ow (output width) determine the input and output port bus widths as per the selections shown in table 3, ?bus matching set-up?. 9 bit bytes or 18 bit words can be written into and read from the queues. when writing to or reading from the multi-queue in a bus matching mode, the device orders data in a ?little endian? format. see figure 3, bus matching byte arrangement for details. the full flag and almost full flag operation is always based on writes and reads of data widths determined by the write port width. for example, if the input port is x18 and the output port is x9, then two data reads from a full queue will be required to cause the full flag to go high (queue not full). conversely, the output valid flag and almost empty flag operations are always based on writes and reads of data widths determined by the read port. for example, if the input port is x9 and the output port is x18, two write operations will be required to cause the output valid flag of an empty queue to go low, output valid (queue is not empty). note, that the input port serves all queues within a device, as does the output port, therefore the input bus width to all queues is equal (determined by the input port size) and the output bus width from all queues is equal (determined by the output port size). full flag operation the multi-queue flow-control device provides a single full flag output, ff . the ff flag output provides a full status of the queue currently selected on the write port for write operations. internally the multi-queue flow-control device monitors and maintains a status of the full condition of all queues within it, however only the queue that is selected for write operations has its full status output to the ff flag. this dedicated flag is often referred to as the ?active queue full flag?. when queue switches are being made on the write port, the ff flag output will switch to the new queue and provide the user with the new queue status, on the cycle after a new queue selection is made. the user then has a full status for the new queue one cycle ahead of the wclk rising edge that data can be written into the new queue. that is, a new queue can be selected on the write port via the wradd bus, waden enable and a rising edge of wclk. on the next rising edge of wclk, the ff flag output will show the full status of the newly selected queue. on the second rising edge of wclk following the queue selection, data can be written into the newly selected queue provided that data and enable setup & hold times are met. note, the ff flag will provide status of a newly selected queue one wclk cycle after queue selection, which is one cycle before data can be written to that queue. this prevents the user from writing data to a queue that is full, (assuming that a queue switch has been made to a queue that is actually full). the ff flag is synchronous to the wclk and all transitions of the ff flag occur based on a rising edge of wclk. internally the multi-queue device monitors and keeps a record of the full status for all queues. it is possible that the status of a ff flag maybe changing internally even though that flag is not the active queue flag (selected on the write port). a queue selected on the read port may experience a change of its internal full flag status based on read operations. see figure 9, write queue select, write operation and full flag operation and figure 11, full flag timing in expansion mode for timing information. expansion mode - full flag operation when multi-queue devices are connected in expansion mode the ff flags of all devices should be connected together, such that a system controller monitoring and managing the multi-queue devices write port only looks at a single ff flag (as opposed to a discrete ff flag for each device). this ff flag is only pertinent to the queue being selected for write operations at that time. remember, that when in expansion mode only one multi-queue device can be written to at any moment in time, thus the ff flag provides status of the active queue on the write port. this connection of flag outputs to create a single flag requires that the ff flag output have a high-impedance capability, such that when a queue selection is made only a single device drives the ff flag bus and all other ff flag outputs connected to the ff flag bus are placed into high-impedance. the user does not have to select this high-impedance state, a given multi-queue flow-control device will automatically place its ff flag output into high-impedance when none of its queues are selected for write operations. when queues within a single device are selected for write operations, the ff flag output of that device will maintain control of the ff flag bus. its ff flag will simply update between queue switches to show the respective queue full status. the multi-queue device places its ff flag output into high-impedance based on the 3 bit id code found in the 3 most significant bits of the write queue address bus, wradd. if the 3 most significant bits of wradd match the 3 bit id code setup on the static inputs, id0, id1 and id2 then the ff flag output of the respective device will be in a low-impedance state. if they do not match, then the ff flag output of the respective device will be in a high-impedance state. see figure 11, full flag timing in expansion mode for details of flag operation, including when more than one device is connected in expansion. i w ow write port read port 0 0 x18 x18 0 1 x18 x9 1 0 x9 x18 1 1 x9 x9 table 3 ? ? ? ? ? bus-matching set-up
20 commercial and industrial temperature ranges idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits output valid flag operation the multi-queue flow-control device provides a single output valid flag output, ov . the ov provides an empty status or data output valid status for the data word currently available on the output register of the read port. the rising edge of an rclk cycle that places new data onto the output register of the read port, also updates the ov flag to show whether or not that new data word is actually valid. internally the multi-queue flow-control device monitors and maintains a status of the empty condition of all queues within it, however only the queue that is selected for read operations has its output valid (empty) status output to the ov flag, giving a valid status for the word being read at that time. the nature of the first word fall through operation means that when the last data word is read from a selected queue, the ov flag will go high on the next enabled read, that is, on the next rising edge of rclk while ren is low. when queue switches are being made on the read port, the ov flag will switch to show status of the new queue in line with the data output from the new queue. when a queue selection is made the first data from that queue will appear on the qout data outputs 2 rclk cycles later, the ov will change state to indicate validity of the data from the newly selected queue on this 2 nd rclk cycle also. the previous cycles will continue to output data from the previous queue and the ov flag will indicate the status of those outputs. again, the ov flag always indicates status for the data currently present on the output register. the ov flag is synchronous to the rclk and all transitions of the ov flag occur based on a rising edge of rclk. internally the multi-queue device monitors and keeps a record of the output valid (empty) status for all queues. it is possible that the status of an ov flag may be changing internally even though that respective flag is not the active queue flag (selected on the read port). a queue selected on the write port may experience a change of its internal ov flag status based on write operations, that is, data may be written into that queue causing it to become ?not empty?. see figure 12, read queue select, read operation and figure 13, output valid flag timing for details of the timing. expansion mode ? output valid flag operation when multi-queue devices are connected in expansion mode, the ov flags of all devices should be connected together, such that a system controller monitoring and managing the multi-queue devices read port only looks at a single ov flag (as opposed to a discrete ov flag for each device). this ov flag is only pertinent to the queue being selected for read operations at that time. remember, that when in expansion mode only one multi-queue device can be read from at any moment in time, thus the ov flag provides status of the active queue on the read port. this connection of flag outputs to create a single flag requires that the ov flag output have a high-impedance capability, such that when a queue selection is made only a single device drives the ov flag bus and all other ov flag outputs connected to the ov flag bus are placed into high-impedance. the user does not have to select this high-impedance state, a given multi-queue flow-control device will automatically place its ov flag output into high-impedance when none of its queues are selected for read operations. when queues within a single device are selected for read operations, the ov flag output of that device will maintain control of the ov flag bus. its ov flag will simply update between queue switches to show the respective queue output valid status. the multi-queue device places its ov flag output into high-impedance based on the 3 bit id code found in the 3 most significant bits of the read queue address bus, rdadd. if the 3 most significant bits of rdadd match the 3 bit id code setup on the static inputs, id0, id1 and id2 then the ov flag output of the respective device will be in a low-impedance state. if they do not match, then the ov flag output of the respective device will be in a high-impedance state. see figure 13, output valid flag timing for details of flag operation, including when more than one device is connected in expansion. almost full flag as previously mentioned the multi-queue flow-control device provides a single programmable almost full flag output, paf . the paf flag output provides a status of the almost full condition for the active queue currently selected on the write port for write operations. internally the multi-queue flow-control device monitors and maintains a status of the almost full condition of all queues within it, however only the queue that is selected for write operations has its full status output to the paf flag. this dedicated flag is often referred to as the ?active queue almost full flag?. the position of the paf flag boundary within a queue can be at any point within that queues depth. this location can be user programmed via the serial port or one of the default values (8 or 128) can be selected if the user has performed default programming. as mentioned, every queue within a multi-queue device has its own almost full status, when a queue is selected on the write port, this status is output via the paf flag. the paf flag value for each queue is programmed during multi-queue device programming (along with the number of queues, queue depths and almost empty values). the paf offset value, m, for a respective queue can be programmed to be anywhere between ?0? and ?d?, where ?d? is the total memory depth for that queue. the paf value of different queues within the same device can be different values. when queue switches are being made on the write port, the paf flag output will switch to the new queue and provide the user with the new queue status, on the second cycle after a new queue selection is made, on the same wclk cycle that data can actually be written to the new queue. that is, a new queue can be selected on the write port via the wradd bus, waden enable and a rising edge of wclk. on the second rising edge of wclk following a queue selection, the paf flag output will show the full status of the newly selected queue. the paf is flag output is double register buffered, so when a write operation occurs at the almost full boundary causing the selected queue status to go almost full the paf will go low 2 wclk cycles after the write. the same is true when a read occurs, there will be a 2 wclk cycle delay after the read operation. so the paf flag delays are: from a write operation to paf flag low is 2 wclk + t waf the delay from a read operation to paf flag high is t skew2 +wclk + t waf note, if t skew is violated there will be one added wclk cycle delay. the paf flag is synchronous to the wclk and all transitions of the paf flag occur based on a rising edge of wclk. internally the multi-queue device monitors and keeps a record of the almost full status for all queues. it is possible that the status of a paf flag maybe changing internally even though that flag is not the active queue flag (selected on the write port). a queue selected on the read port may experience a change of its internal almost full flag status based on read operations. the multi-queue flow-control device also provides a duplicate of the paf flag on the paf [7:0] flag bus, this will be discussed in detail in a later section of the data sheet. see figures 18 and 19 for almost full flag timing and queue switching. almost empty flag as previously mentioned the multi-queue flow-control device provides a single programmable almost empty flag output, pae . the pae flag output provides a status of the almost empty condition for the active queue currently selected on the read port for read operations. internally the multi-queue flow- control device monitors and maintains a status of the almost empty condition of all queues within it, however only the queue that is selected for read operations has its empty status output to the pae flag. this dedicated flag is often referred to as the ?active queue almost empty flag?. the position of the pae flag boundary
21 idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits commercial and industrial temperature ranges within a queue can be at any point within that queues depth. this location can be user programmed via the serial port or one of the default values (8 or 128) can be selected if the user has performed default programming. as mentioned, every queue within a multi-queue device has its own almost empty status, when a queue is selected on the read port, this status is output via the pae flag. the pae flag value for each queue is programmed during multi- queue device programming (along with the number of queues, queue depths and almost full values). the pae offset value, n, for a respective queue can be programmed to be anywhere between ?0? and ?d?, where ?d? is the total memory depth for that queue. the pae value of different queues within the same device can be different values. when queue switches are being made on the read port, the pae flag output will switch to the new queue and provide the user with the new queue status, on the second cycle after a new queue selection is made, on the same rclk cycle that data actually falls through to the output register from the new queue. that is, a new queue can be selected on the read port via the rdadd bus, raden enable and a rising edge of rclk. on the second rising edge of rclk following a queue selection, the data word from the new queue will be available at the output register and the pae flag output will show the empty status of the newly selected queue. the pae is flag output is double register buffered, so when a read operation occurs at the almost empty boundary causing the selected queue status to go almost empty the pae will go low 2 rclk cycles after the read. the same is true when a write occurs, there will be a 2 rclk cycle delay after the write operation. so the pae flag delays are: from a read operation to pae flag low is 2 rclk + t rae the delay from a write operation to pae flag high is t skew2 + rclk + t rae note, if t skew is violated there will be one added rclk cycle delay. the pae flag is synchronous to the rclk and all transitions of the pae flag occur based on a rising edge of rclk. internally the multi-queue device monitors and keeps a record of the almost empty status for all queues. it is possible that the status of a pae flag maybe changing internally even though that flag is not the active queue flag (selected on the read port). a queue selected on the write port may experience a change of its internal almost empty flag status based on write operations. the multi-queue flow-control device also provides a duplicate of the pae flag on the pae [7:0] flag bus, this will be discussed in detail in a later section of the data sheet. see figures 20 and 21 for almost empty flag timing and queue switching.
22 commercial and industrial temperature ranges idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits table 4 flag operation boundaries & timing output valid, ov flag boundary i/o set-up ov boundary condition in18 to out18 or in9 to out9 ov goes low after 1 st write (both ports selected for same queue (see note below for timing) when the 1 st word is written in) in18 to out9) ov goes low after 1 st write (both ports selected for same queue (see note below for timing) when the 1 st word is written in) in9 to out18 ov goes low after 2 nd write (both ports selected for same queue (see note below for timing) when the 1 st word is written in) note: 1. ov timing assertion: write to ov low: t skew1 + rclk + t rov if t skew1 is violated there may be 1 added clock: t skew1 + 2 rclk + t rov de-assertion: read operation to ov high: t rov note: d = queue depth ff timing assertion: write operation to ff low: t wff de-assertion: read to ff high: t skew1 + t wff if t skew1 is violated there may be 1 added clock: t skew1 +wclk +t wff full flag, ff boundary i/o set-up ff boundary condition in18 to out18 or in9 to out9 ff goes low after d+1 writes (both ports selected for same queue (see note below for timing) when the 1 st word is written in) in18 to out18 or in9 to out9 ff goes low after d writes (write port only selected for queue (see note below for timing) when the 1 st word is written in) in18 to out9 ff goes low after d writes (both ports selected for same queue (see note below for timing) when the 1 st word is written in) in18 to out9 ff goes low after d writes (write port only selected for queue (see note below for timing) when the 1 st word is written in) in9 to out18 ff goes low after ([d+1] x 2) writes (both ports selected for same queue (see note below for timing) when the 1 st word is written in) in9 to out18 ff goes low after (d x 2) writes (write port only selected for queue (see note below for timing) when the 1 st word is written in)
23 idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits commercial and industrial temperature ranges table 4 flag operation boundaries & timing (continued) note: n = almost empty offset value. default values: if df is low at master reset then n = 8 if df is high at master reset then n = 128 pae n timing assertion: read operation to pae n low: 2 rclk* + t pae de-assertion: write to pae n high: t skew3 + rclk* + t pae if t skew3 is violated there may be 1 added clock: t skew3 + 2 rclk* + t pae * if a queue switch is occurring on the read port at the point of flag assertion or de-assertion there may be one additional rclk clock cycle delay. programmable almost empty flag bus, pae n boundary i/o set-up pae n boundary condition in18 to out18 or in9 to out9 pae n goes high after (both ports selected for same queue when the 1 st n+2 writes word is written in until the boundary is reached) (see note below for timing) in18 to out18 or in9 to out9 pae n goes high after (write port only selected for same queue when the n+1 writes 1 st word is written in until the boundary is reached) (see note below for timing) in18 to out9 pae n goes high after n+1 writes (see below for timing) in9 to out18 pae n goes high after (both ports selected for same queue when the 1 st ([n+2] x 2) writes word is written in until the boundary is reached) (see note below for timing) in9 to out18 pae n goes high after (write port only selected for same queue when the ([n+1] x 2) writes 1 st word is written in until the boundary is reached) (see note below for timing) programmable almost full flag, paf & paf n bus boundary i/o set-up paf & paf n boundary in18 to out18 or in9 to out9 paf / paf n goes low after (both ports selected for same queue when the 1 st d+1-m writes word is written in until the boundary is reached) (see note below for timing) in18 to out18 or in9 to out9 paf / paf n goes low after (write port only selected for same queue when the d-m writes 1 st word is written in until the boundary is reached) (see note below for timing) in18 to out9 paf / paf n goes low after d-m writes (see below for timing) in9 to out18 paf / paf n goes low after ([d+1-m] x 2) writes (see note below for timing) note: d = queue depth m = almost full offset value. default values: if df is low at master reset then m = 8 if df is high at master reset then m= 128 paf timing assertion: write operation to paf low: 2 wclk + t waf de-assertion: read to paf high: t skew2 + wclk + t waf if t skew2 is violated there may be 1 added clock: t skew2 + 2 wclk + t waf paf n timing assertion: write operation to paf n low: 2 wclk* + t paf de-assertion: read to paf n high: t skew3 + wclk* + t paf if t skew3 is violated there may be 1 added clock: t skew3 + 2 wclk* + t paf * if a queue switch is occurring on the write port at the point of flag assertion or de-assertion there may be one additional wclk clock cycle delay. note: n = almost empty offset value. default values: if df is low at master reset then n = 8 if df is high at master reset then n = 128 pae timing assertion: read operation to pae low: 2 rclk + t rae de-assertion: write to pae high: t skew2 + rclk + t rae if t skew2 is violated there may be 1 added clock: t skew2 + 2 rclk + t rae programmable almost empty flag, pae boundary i/o set-up pae assertion in18 to out18 or in9 to out9 pae goes high after n+2 (both ports selected for same queue when the 1 st writes word is written in until the boundary is reached) (see note below for timing) in18 to out9 pae goes high after n+1 (both ports selected for same queue when the 1 st writes word is written in until the boundary is reached) (see note below for timing) in9 to out18 pae goes high after (both ports selected for same queue when the 1 st ([n+2] x 2) writes word is written in until the boundary is reached) (see note below for timing)
24 commercial and industrial temperature ranges idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits paf n flag bus operation the idt72v51433/72v51443/72v51453 multi-queue flow-control devices can be configured for up to 16 queues, each queue having its own almost full status. an active queue has its flag status output to the discrete flags, ff and paf , on the write port. queues that are not selected for a write operation can have their paf status monitored via the paf n bus. the paf n flag bus is 8 bits wide, so that 8 queues at a time can have their status output to the bus. if 9 or more queues are setup within a device then there are 2 methods by which the device can share the bus between queues, "direct" mode and "polled" mode depending on the state of the fm (flag mode) input during a master reset. if 8 or less queues are setup within a device then each will have its own dedicated output from the bus. if 8 or less queues are setup in single device mode, it is recommended to configure the paf n bus to polled mode as it does not require using the write address (wradd). paf n - direct bus if fm is low at master reset then the paf n bus operates in direct (addressed) mode. in direct mode the user can address the sector of queues they require to be placed on to the paf n bus. for example, consider the operation of the paf n bus when 10 queues have been setup. to output status of the first sector, queue[0:7] the wradd bus is used in conjunction with the fstr ( paf flag strobe) input and wclk. the address present on the significant bit of the wradd bus with fstr high will be selected as the sector address on a rising edge of wclk. so to address sector 1, queue[0:7] the wradd bus should be loaded with ?xxxxxx0?, the paf n bus will change status to show the new sector selected 1 wclk cycle after sector selection. paf n[0:7] gets status of queues, queue[0:7] respectively. to address the second sector, queue[8:15], the wradd address is ?xxxxxx1?. paf [0:1] gets status of queues, queue[9:10] respectively. remem- ber, only 10 queues were setup, so when sector 2 is selected the unused outputs paf [2:7] will be don't care states. note, that if a read or write operation is occurring to a specific queue, say queue ?x? on the same cycle as a sector switch which will include the queue ?x?, then there may be an extra wclk cycle delay before that queues status is correctly shown on the respective output of the paf n bus. however, the active paf flag will show correct status at all times. sectors can be selected on consecutive clock cycles, that is the sector on the paf n bus can change every wclk cycle. also, data present on the input bus, din, can be written into a queue on the same wclk rising edge that a sector is being selected, the only restriction being that a write queue selection and paf n sector selection cannot be made on the same cycle. if 8 or less queues are setup then queues, queue[0:7] have their paf status output on paf [0:7] constantly. when the multi-queue devices are connected in expansion of more than one device the paf n busses of all devices are connected together, when switching between sectors of different devices the user must utilize the 3 most significant bits of the wradd address bus (as well as the 2 lsb?s). these 3 msb?s correspond to the device id inputs, which are the static inputs, id0, id1 & id2. please refer to figure 23 paf n - direct mode sector selection for timing information. also refer to table 1, write address bus, wradd . paf n ? polled bus if fm is high at master reset then the paf n bus operates in polled (looped) mode. in polled mode the paf n bus automatically cycles through the 2 sectors within the device regardless of how many queues have been setup in the part. every rising edge of the wclk causes the next sector to be loaded on the paf n bus. the device configured as the master (mast input tied high), will take control of the paf n after mrs goes low. for the whole wclk cycle that the first sector is on paf n the fsync ( paf n bus sync) output will be high, for the 2nd sector, this fsync output will be low. this fsync output provides the user with a mark with which they can synchronize to the paf n bus, fsync is always high for the wclk cycle that the first sector of a device is present on the paf n bus. when devices are connected in expansion mode, only one device will be set as the master, mast input tied high, all other devices will have mast tied low. the master device is the first device to take control of the paf n bus and will place its first sector on the bus on the rising edge of wclk after the mrs input goes high. for the next 3 wclk cycles the master device will maintain control of the paf n bus and cycle its sectors through it, all other devices hold their paf n outputs in high-impedance. when the master device has cycled its sectors it passes a token to the next device in the chain and that device assumes control of the paf n bus and then cycles its sectors and so on, the paf n bus control token being passed on from device to device. this token passing is done via the fxo outputs and fxi inputs of the devices (? paf expansion out? and ? paf expansion in?). the fxo output of the master device connects to the fxi of the second device in the chain and the fxo of the second connects to the fxi of the third and so on. the final device in a chain has its fxo connected to the fxi of the first device, so that once the paf n bus has cycled through all sectors of all devices, control of the paf n will pass to the master device again and so on. the fsync of each respective device will operate independently and simply indicate when that respective device has taken control of the bus and is placing its first sector on to the paf n bus. when operating in single device mode the fxi input must be connected to the fxo output of the same device. in single device mode a token is still required to be passed into the device for accessing the paf n bus. please refer to figure 26, paf n bus ? polled mode for timing information. pae n flag bus operation the idt72v51433/72v51443/72v51453 multi-queue flow-control devices can be configured for up to 16 queues, each queue having its own almost empty status. an active queue has its flag status output to the discrete flags, ov and pae , on the read port. queues that are not selected for a read operation can have their pae status monitored via the pae n bus. the pae n flag bus is 8 bits wide, so that 8 queues at a time can have their status output to the bus. if 9 or more queues are setup within a device then there are 2 methods by which the device can share the bus between queues, "direct" mode and "polled" mode depending on the state of the fm (flag mode) input during a master reset. if 8 or less queues are setup within a device then each will have its own dedicated output from the bus. if 8 or less queues are setup in single device mode, it is recommended to configure the paf n bus to polled mode as it does not require using the write address (wradd). pae n - direct bus if fm is low at master reset then the pae n bus operates in direct (addressed) mode. in direct mode the user can address the sector of queues they require to be placed on to the pae n bus. for example, consider the operation of the pae n bus when 10 queues have been setup. to output status of the first sector, queue[0:7] the rdadd bus is used in conjunction with the estr ( pae flag strobe) input and rclk. the address present on the least significant bit of the rdadd bus with estr high will be selected as the sector address on a rising edge of rclk. so to address sector 1, queue[0:7] the rdadd bus should be loaded with ?xxxxxx0?, the pae n bus will change status to show the new sector selected 1 rclk cycle after sector selection. pae n[0:7] gets status of queues, queue[0:7] respectively. to address the 2nd sector, queue[8:15], the rdadd address is ?xxxxxx1?. pae [0:1] gets status of queues, queue[9:10] respectively. remember, only 10
25 idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits commercial and industrial temperature ranges queues were setup, so when sector 2 is selected the unused outputs pae [2:7] will be don't care states. note, that if a read or write operation is occurring to a specific queue, say queue ?x? on the same cycle as a sector switch which will include the queue ?x?, then there may be an extra rclk cycle delay before that queues status is correctly shown on the respective output of the pae n bus. sectors can be selected on consecutive clock cycles, that is the sector on the pae n bus can change every rclk cycle. also, data can be read out of a queue on the same rclk rising edge that a sector is being selected, the only restriction being that a read queue selection and pae n sector selection cannot be made on the same rclk cycle. if 8 or less queues are setup then queues, queue[0:7] have their pae status output on pae [0:7] constantly. when the multi-queue devices are connected in expansion of more than one device the pae n busses of all devices are connected together, when switching between sectors of different devices the user must utilize the 3 most significant bits of the rdadd address bus (as well as the 2 lsb?s). these 3 msb?s correspond to the device id inputs, which are the static inputs, id0, id1 & id2. please refer to figure 22, pae n - direct mode sector selection for timing information. also refer to table 2, read address bus, rdadd . pae n ? polled bus if fm is high at master reset then the pae n bus operates in polled (looped) mode. in polled mode the pae n bus automatically cycles through the 2 sectors within the device regardless of how many queues have been setup in the part. every rising edge of the rclk causes the next sector to be loaded on the pae n bus. the device configured as the master (mast input tied high), will take control of the pae n after mrs goes low. for the whole rclk cycle that the first sector is on pae n the esync ( pae n bus sync) output will be high, for the 2nd sector, this esync output will be low. this esync output provides the user with a mark with which they can synchronize to the pae n bus, esync is always high for the rclk cycle that the first sector of a device is present on the pae n bus. when devices are connected in expansion mode, only one device will be set as the master, mast input tied high, all other devices will have mast tied low. the master device is the first device to take control of the pae n bus and will place its first sector on the bus on the rising edge of rclk after the mrs input goes low. for the next 3 rclk cycles the master device will maintain control of the pae n bus and cycle its sectors through it, all other devices hold their pae n outputs in high-impedance. when the master device has cycled its sectors it passes a token to the next device in the chain and that device assumes control of the pae n bus and then cycles its sectors and so on, the pae n bus control token being passed on from device to device. this token passing is done via the exo outputs and exi inputs of the devices (? pae expansion out? and ? pae expansion in?). the exo output of the master device connects to the exi of the second device in the chain and the exo of the second connects to the exi of the third and so on. the final device in a chain has its exo connected to the exi of the first device, so that once the pae n bus has cycled through all sectors of all devices, control of the pae n will pass to the master device again and so on. the esync of each respective device will operate independently and simply indicate when that respective device has taken control of the bus and is placing its first sector on to the pae n bus. when operating in single device mode the exi input must be connected to the exo output of the same device. in single device mode a token is still required to be passed into the device for accessing the pae n bus. please refer to figure 27, pae n bus ? polled mode for timing information.
26 commercial and industrial temperature ranges idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits d17-d9 a a b b (a) x18 input to x18 output - big endian (b) x18 input to x18 output - little endian write to queue read from queue byte order on input port: byte order on output port: ba read from queue a (c) x18 input to x9 output - big endian 1st: read from queue b 2nd: read from queue b (d) x18 input to x9 output - little endian 1st: read from queue a 2nd: read from queue a (a) x9 input to x18 output - big endian 1st: write to queue byte order on input port: b 2nd: write to queue byte order on output port: ab read from queue (a) x9 input to x18 output - little endian b a read from queue 5939 drw07 b e iw ow h l h b e iw ow l h l b e iw ow h h l b e iw ow l l h b e iw ow h l l b e iw ow l l l d8-d0 q17-q9 q8-q0 q17-q9 q8-q0 q17-q9 q8-q0 q17-q9 q8-q0 q17-q9 q8-q0 q17-q9 q8-q0 d17-d9 d8-d0 d17-q9 d8-q0 q17-q9 q8-q0 q17-q9 q8-q0 figure 3. bus-matching byte arrangement
27 idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits commercial and industrial temperature ranges t rs mrs wen ren t rss fstr, estr 5939 drw08 df dfm high = default programming low = serial programming high = offset value is 128 low = offset value is 8 t rss t rss t rsr seni waden, raden t rss t rss t rss ow, iw fm high = looped low = strobed (direct) id0, id1, id2 t rss mast high = master device low = slave device t rss t rss t rss ff t rsf ov t rsf paf t rsf pae t rsf t rsf t rsf qn t rsf logic "1" if oe is low and device is master high-z if oe is high or device is slave logic "1" if master device high-z if slave device logic "1" if master device high-z if slave device high-z if slave device logic "0" if master device high-z if slave device logic "0" if master device logic "1" if master device high-z if slave device paf n pae n high-z if slave device logic ?0" if master device figure 4. master reset notes: 1. oe can toggle during this period. 2. prs should be high during a mrs .
28 commercial and industrial temperature ranges idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits figure 6. serial port connection for serial programming dfm mrs seni seno mq1 si so sclk dfm mrs seni seno mq2 si so sclk dfm mrs seni seno mqn si so sclk serial enable serial input serial clock default mode dfm = 0 master reset serial loading complete 5939 drw10 figure 5. partial reset notes: 1. for a partial reset to be performed on a queue, that queue must be selected on both the write and read ports. 2. the queue must be selected a minimum of 2 clock cycles before the partial reset takes place, on both the write and read ports . 3. the partial reset must be low for a minimum of 1 wclk and 1 rclk cycle. 4. writing or reading to the queue (or a queue change) cannot occur until a minimum of 3 clock cycles after the partial reset ha s gone high, on both the write and read ports. 5. the paf flag output for qx on the paf n flag bus may update one cycle later than the active paf flag. 6. the pae flag output for qx on the pae n flag bus may update one cycle later than the active pae flag. wclk rclk rdadd t ah t as t qh t qs qx raden r-2 r-1 r prs r+2 r+1 t prsh t prss ren t ens r+3 t ens t rov ov t rae pae 5939 drw09 wen waden t ah t as wradd qx w-2 w-1 w w+1 w+2 t qh t qs t ens w+3 t ens ff t wff paf t waf active bus paf -qx (5) t paf active bus pae -qx (6) t pae t prsh t prss
29 idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits commercial and industrial temperature ranges figure 7. serial programming rclk wen seno (mq1) ff waden/ fstr raden/ estr ov wclk 5939 drw11 t wff t ens t rov t pcwq t qs t qh t qs t qh t pcrq high - z high - z (slave device) (slave device) so (mq1) mrs sclk seni (mq1) si (mq1) t rsr t seno 1st 2nd nth 1st 2nd nth 1st 2nd nth t sens seno (mq2) seno (mq8) b 12 b 11 t sds b 1n t sdh b 21 b 22 b 2n b 81 b 82 b 8n b 21 b 22 b 2n b 81 b 82 b 8n t seno t seno t sclk t sckl t sckh programming complete 1st device in chain 2nd device in chain final device in chain t sdo t sdop t senop t senop notes: 1. seni can be toggled during serial loading. once serial programming of a device is complete, the seni and si inputs become transparent. seni seno and si so. 2. dfm is low during master reset to provide serial programming mode, df is don't care. 3. when seno of the final device is low no further serial loads will be accepted. 4. n = 19+(qx72); where q is the number of queues required for the idt72v51433/72v51443/72v51453. 5. this diagram illustrates 8 devices in expansion. 6. programming of all devices must be complete ( seno of the final device is low), before any write or read port operations can take place, this includes queue selections.
30 commercial and industrial temperature ranges idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits dfm mrs seni seno mq1 wclk serial enable (can be tied low) wclk default mode dfm = 1 master reset serial loading complete dfm mrs seni seno mq2 wclk dfm mrs seni seno mqn wclk rclk wen ff waden/ fstr raden/ estr ov 5939 drw11a t wff t ens t rov t pcwq t qs t qh t qs t qh t pcrq high - z high - z (slave device) (slave device) seno (mq1) t seno seno (mq2) seno (mq8) t seno wclk mrs 1st device in chain 1st 2nd nth 3rd 2nd device in chain 1st 2nd nth final device in chain 1st 2nd nth programming complete t seno serial port connection for default programming si so xsi so xsi so x figure 8. default programming notes: 1. this diagram illustrates multiple devices connected in expansion. the seno of the final device in a chain is the "programming complete" signal. 2. seni of the first device in the chain can be held low 3. the seno of a device should connect to the seni of the next device in the chain. the final device seno is used to indicate programming complete. 4. when default programming is complete the seno of the final device will go low. 5. sclk is not used and can be tied low. 6. programming of all devices must be complete ( seno of the final device is low), before any write or read port operations can take place, this includes queue selections.
31 idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits commercial and industrial temperature ranges figure 9. write queue select, write operation and full flag operation wclk waden t qh t qs t ah t as wradd q x ff t wff 5939 drw12 wen t ens t ah t as q y t qh t qs t dh t ds q x w d t dh q y w d-2 w d-1 q y t dh din t wff t wff previous q status no writes queue full *a* *b* *c* *d* *e* *f* *g* t ds q y w d t ds t dh t enh t wff t wff rclk t skew1 t qs t qh ren t ens rdadd q y raden qout t a previous q, word, w previous q, w +1 pft t a qy, w 0 pft t a t a qy, w 1 qy, w 2 *h* *i* *j* t as t ah *aa* *bb* *cc* *dd* *ee* *ff* t ds note : oe is active low. cycle: *a* queue, qx is selected on the write port. the ff flag is providing status of a previously selected queue, within the same device. *aa* queue, qy is selected for read operations. *b* the ff flag output updates to show the status of qx, it is not full. *bb* word w+1 is read from the previous queue regardless of ren due to fwft. *c* word, wd is written into qx. this causes qx to go full. *cc* word, w0 is read from qy regardless of ren , this is due to the fwft effect. *d* queue, qy is selected within the same device as qx. a write to qx cannot occur on this cycle because it is full, ff is low. *dd* no reads occur, ren is high. *e* again, a write to qx cannot occur on this cycle because it is full, ff is low. the ff flag updates after time t wff to show that queue, qy is not full. *ee* word, w1 is read from qy, this causes qy to go ?not full?, ff flag goes high after time, t skew1 + t wff . note, if t skew1 is violated the time ff high will be: t skew1 + wclk + t wff . *f* word, wd-2 is written into qy. *ff* word, w2 is read from qy. *g* word, wd-1 is written into qy. *h* word, wd is written into qy, this causes qy to go full, ff goes low. *i* no writes occur to qy. *j* qy goes ?not full? based on reading word w1 from qy on cycle *ee*.
32 commercial and industrial temperature ranges idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits 5939 drw12a w1 w2 w3 wclk t enh wen dn t dh t ds t ds t dh t ds t dh rclk t skew1 12 t ens ren t a w1 qy fwft t a t a w2 qy fwft w3 qy last word read out of queue qout t rov ov t rov t ens figure 10. write operations & first word fall through notes: 1. qy has previously been selected on both the write and read ports. 2. oe is low. 3. the first word latency = t skew1 + rclk + t a . if t skew1 is violated an additional rclk cycle must be added.
33 idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits commercial and industrial temperature ranges wclk waden t qh t qs t ah t as wradd d 1 q 12 ff (device 1) t fflz 5939 drw13 wen t ens t ah t as t ah t as t qh t qs d 2 q 9 t qh t qs t dh t ds w d d 1 q12 t dh t ds din t wff t wff high-z rclk 1 2 t enh t ens t enh addr=001 1100 d 1 q 5 t wff w d d 1 q5 t ffhz t wff high-z ff (device 2) t ffhz high-z t fflz t skew1 addr=001 0101 t ah t as rdadd d 1 q 5 t qh t qs raden *a* *b* *c* *d* *e* *f* *g* *h* *i* no write *j* qout t a t a previous q w x-1 previous q w x pft d 1 -q 5 word w 0 pft *aa* *bb* *cc* figure 11. full flag timing in expansion mode note: 1. ren = high. cycle: *a* queue, q12 of device 1 is selected on the write port. the ff flag of device 1 is in high-impedance, the write port of device 2 was previously selected. wen is high so no write occurs. *aa* queue, q5 of device 1 is selected on the read port. *b* the ff flag of device 2 goes to high-impedance and the ff flag of device 1 goes to low-impedance, logic high indicating that d1 q12 is not full. wen is high so no write occurs. *bb* word, wx is read from the previously selected queue, (due to fwft). *c* word, wd is written into q12 of d1. this write operation causes q12 to go full, ff goes low. *cc* the first word from q5 of d1 selected on cycle *aa* is read out, this occurred regardless of ren due to fwft. this read caused q5 to go not full, therefore the ff flag will go high after: t skew1 + t wff . note if t skew1 is violated the time to ff flag high is t skew1 + wlck + t wff . *d* queue, q5 of device 1 is selected on the write port. no write occurs on this cycle. *e* the ff flag updates to show the status of d1 q5, it is not full, ff goes high. *f* word, wd is written into q5 of d1. this causes the queue to go full, ff goes low. *g* no write occurs regardless of wen , the ff flag is low preventing writes. *h* the ff flag goes high due to the read from q5 of d1 on cycle *cc*. (this read is not an enabled read, it is due to the fwft operation ). *i* queue, q9 of device 2 is selected on the write port. *j* the ff flag of device 1 goes to high-impedance, this device was deselected on the write port on cycle *i*. the ff flag of device 2 goes to low-impedance and provides status of q9 of d2.
34 commercial and industrial temperature ranges idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits figure 12. read queue select, read operation rclk 5939 drw14 t ah t as q f rdadd t qh t qs raden ren t ens t enh t ens t ah t as q g t qh t qs q out q p w n-3 t a q p w n-2 t a previous q, q p w n-1 t a t a q p w n t a q f w 0 pft t a q f w 1 q f w 2 t rov ov previous q 1 2 *a* *b* *c* *d* *e* *f* *g* *h* pft *i* cycle: *a* word wn- 3 is read from a previously selected queue qp on the read port. *b* wn- 2 is read. *c* reads are disabled, wn- 1 remains on the output bus. *d* a new queue, q f is selected for read operations. *e* due to the first word fall through (fwft) effect, a read from the previous queue qp will take place, wn from qp is placed onto the output bus regardless of ren . *f* the next word available in the new queue, q f -w 0 falls through to the output bus, again this is regardless of ren . *g* a new queue, q g is selected for read operations. (this queue is an empty queue). word, w 1 is also read from q f . *h* word, w 1 is read from q f . this occurs regardless of ren due to fwft. *i* word w 2 from q f remains on the output bus because q g is empty. the output valid flag, ov goes high to indicate that the current word is not valid, i.e. q g is empty. w 2 is the last word in q g .
35 idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits commercial and industrial temperature ranges figure 13. output valid flag timing (in expansion mode) rclk raden t qh t qs t ah t as rdadd d 1 q 9 ov (device 1) 5939 drw15 t ens ren t ah t as t qh t qs qout (device 1) t rov high-z wclk d 1 q 15 ov (device 2) t ovhz t skew1 t ah t as wradd d 1 q 15 t qh t qs waden t dh t ds d 1 q 15 w 0 din t a d 1 q 9 w d last word t olz t a d 1 q 15 pft w e-1 t a d 1 q 15 w e last word t a w 0 q 15 d 1 t ovlz t rov t rov t rov wen t ens t enh *a* *b* *c* *d* *e* *f* *g* *h* *i* cycle: *a* queue 9 of device 1 is selected for read operations. the ov is currently being driven by device 2, a queue within device 2 is selected for reads. device 2 also has control of qout bus, its qout outputs are in low-impedance. this diagram only shows the qout outputs of device 1. (reads are disabled). *b* reads are now enabled. a word from the previously selected queue of device 2 will be read out. *c* the qout of device 1 goes to low-impedance and word wd is read from q9 of d1. this happens to be the last word of q9. device 2 places its qout outputs into high-impedance, device 1 has control of the qout bus. the ov flag of device 2 goes to high-impedance and device 1 takes control of ov . the ov flag of device 1 goes low to show that wd of q9 is valid. *d* queue 15 of device 1 is selected for read operations. the last word of q9 was read on the previous cycle, therefore ov goes high to indicate that the data on the qout is not valid (q9 was read to empty). word, wd remains on the output bus. *e* the last word of q9 remains on the qout bus, ov is high, indicating that this word has been previously read. *f* the next word (we-1), available from the newly selected queue, q15 of device 1 is now read out. this will occur regardless of ren , 2 rclk cycles after queue selection due to the fwft operation. the ov flag now goes low to indicate that this word is valid. *g* the last word, we is read from q15, this queue is now empty. *h* the ov flag goes high to indicate that q15 was read to empty on the previous cycle. *i* due to a write operation the ov flag goes low and data word w0 is read from q15. the latency is: t skew1 + 1*rclk + t rov .
36 commercial and industrial temperature ranges idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits figure 14. read queue selection with reads disabled figure 15. read queue select, read operation and oe timing rclk 5939 drw16 t ah t as q n rdadd t qh t qs raden ren t ens t ah t as q p t qh t qs q out q p w d t a q p w d+1 t a t a q p w d+2 t a q n w x+1 ov t ens t enh t a q p w d+3 q p w d+4 *a* *b* *c* *d* *e* *f* *g* *h* *i* *j* t a t enh q n w x rclk raden t qh t qs t ah t as rdadd q a ov 5939 drw17 qout t rov t olz t a q a w 0 pft t a t a t ens ren t ah t as q b t qh t qs oe t oe t a previous data in o/p register t a q a w 1 no read q b is empty t rov *b* *c* *e* *f* *d* *a* *h* *i* *g* t enh t ens q a w 2 q a w 3 q a w 4 t ohz cycle: *a* word wd+1 is read from the previously selected queue, qp. *b* reads are disabled, word wd+1 remains on the output bus. *c* a new queue, qn is selected for read port operations. *d* due to fwft operation word, wd+2 of qp is read out regardless of ren . *e* the next available word wx of qn is read out regardless of ren , 2 rclk cycles after queue selection. this is fwft operation. *f* the queue, qp is again selected. *g* word wx+1 is read from qn regardless of ren , this is due to fwft. *h* word wd+3 is read from qp, this read occurs regardless of ren due to fwft operation. *i* word wd+4 is read from qp. *j* reads are disabled on this cycle, therefore no further reads occur. notes: 1. the output valid flag, ov is high therefore the previously selected queue has been read to empty. the output enable input is asynchronous, therefore the qout output bus will go to low-impedance after time t olz . the data currently on the output register will be available on the output after time t oe . this data is the previous data on the output register, this is the last word read out of the previous queue. 2. in expansion mode the oe inputs of all devices should be connected together. this allows the output busses of all devices to be high-impedance controll ed. cycle: *a* queue a is selected for reads. no data will fall through on this cycle, the previous queue was read to empty. *b* no data will fall through on this cycle, the previous queue was read to empty. *c* word, w0 from qa is read out regardless of ren due to fwft operation. the ov flag goes low indicating that word w0 is valid. *d* reads are disabled therefore word, w0 of qa remains on the output bus. *e* reads are again enabled so word w1 is read from qa. *f* word w2 is read from qa. *g* queue, qb is selected on the read port. this queue is actually empty. word, w3 is read from qa. *h* word, w4 falls through from qa. *i* output valid flag, ov goes high to indicate that qb is empty. data on the output port is no longer valid. output enable is taken high, this is asynchronous so the output bus goes to high-impedance after time, t ohz .
37 idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits commercial and industrial temperature ranges rclk raden qout ren t ah t as 0001xxxx rdadd t a null queue select *a* *b* *c* *e* *f* t qh t ens q1 wn-3 q1 wn-2 q1 wn-1 t a t a q1 wn t a q4 w0 fwft ov t rov t rov 5938 drw18 select new queue *d* 00000100 t ah t as t qh t qs t enh t qs figure 16. read operation and null queue select notes: 1. the purpose of the null queue operation is so that the user can stop reading a block (packet) of data from a queue without fi lling the 2 stage output pipeline with the next words from that queue. 2. please see figure 17, null queue flow diagram . cycle: *a* null q of device 0 (32nd queue) is selected, when word wn-1 from previously selected q1 is read. *b* ren is high and wn (last word of the packet) of q1 is pipelined onto the o/p register. note: *b* and *c* are a minimum 2 rclk cycles between q selects. *c* the null q is seen as an empty queue on the read side, therefore wn of q1 remains in the o/p register and ov goes high. *d* a new q, q4 is selected and the 1st word of q4 will fall through present on the o/p register on cycle *f*. 5939 drw19 queue 1 memory *a* null queue *b* null queue *c* o/p reg. *d* *e* *f* null queue queue 4 memory q1 wn queue 4 memory o/p reg. o/p reg. o/p reg. o/p reg. o/p reg. qn wn-1 q1 wn q1 wn q1 wn q1 wn q1 wn q1 wn q4 w0 q1 wn q4 w1 q4 w0 figure 17. null queue flow diagram
38 commercial and industrial temperature ranges idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits wclk waden t qh t qs t ah t as wradd d 1 q 5 paf (device 1) t aflz 5939 drw20 wen t ens t ah t as t qh t qs t dh t ds w d-m din t waf t waf high-z t enh d 1 q 9 paf (device 2) t ffhz 12 d 1 q 5 *b* *c* *e* *f* *d* *a* figure 18. almost full flag timing and queue switch figure 19. almost full flag timing wclk wen paf rclk t waf ren 5939 drw21 d - (m+1) words in queue d - m words in queue 1 2 1 d-(m+1) words in queue t waf t enh t ens t skew2 t enh t ens t clkl t clkl cycle: *a* queue 5 of device 1 is selected on the write port. a queue within device 2 had previously been selected. the paf output of device 1 is high-impedance. *b* no write occurs. *c* word, wd-m is written into q5 causing the paf flag to go from high to low. the flag latency is 2 wclk cycles + t waf . *d* queue 9 if device 1 is now selected for write operations. this queue is not almost full, therefore the paf flag will update after a 2 wclk + t waf latency. *e* the paf flag goes low based on the write 2 cycles earlier. *f* the paf flag goes high due to the queue switch to q9. note: 1. the waveform here shows the paf flag operation when no queue switches are occurring and a queue selected on both the write and read ports is being written to then read from at the almost full boundary. flag latencies: assertion: 2*wclk + t waf de-assertion: t skew2 + wclk + t waf if t skew2 is violated there will be one extra wclk cycle.
39 idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits commercial and industrial temperature ranges figure 20. almost empty flag timing and queue switch figure 21. almost empty flag timing rclk raden t qh t qs t ah t as rdadd d 1 q 12 pae (device 1) t aelz 5939 drw22 ren t ah t as t qh t qs t olz qout t rae t rae high-z d 1 q 15 pae (device 2) t aehz high high-z t a d 1 q 12 w n high-z *b* *c* *e* *f* *d* *a* t a d 1 q 12 w n+1 t a d 1 q 15 w 0 t a d 1 q 15 w 1 *g* wclk t enh t clkh t clkl wen pae rclk t ens n+1 words in queue t rae t skew2 t rae 12 ren 5939 drw23 t ens t enh n+2 words in queue n+1 words in queue cycle: *a* queue 12 of device 1 is selected on the read port. a queue within device 2 had previously been selected. the pae flag output and the data outputs of device 1 are high-impedance. *b* no read occurs. *c* the pae flag output now switches to device 1. word, wn is read from q12 due to the fwft operation. this read operation from q12 is at the almost empty boundary, therefore pae will go low 2 rclk cycles later. *d* q15 of device 1 is selected. *e* the pae flag goes low due to the read from q12 2 rclk cycles earlier. word wn+1 is read out due to the fwft operation. *f* word, w0 is read from q15 due to the fwft operation. the pae flag goes high to show that q15 is not almost empty. note: 1. the waveform here shows the pae flag operation when no queue switches are occurring and a queue selected on both the write and read ports is being written to then read from at the almost empty boundary. flag latencies: assertion: 2*rclk + t rae de-assertion: t skew2 + rclk + t rae if t skew2 is violated there will be one extra rclk cycle.
40 commercial and industrial temperature ranges idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits figure 22. pae n - direct mode - sector selection rclk t sth t sts t qh t qs 001xxxx1 5939 drw24 rdadd estr device 1 sector 2 t qs t qh 001xxxx0 device 1 sector 1 t qs t qh 001xxxx1 device 1 sector 2 t sts t sth pae n t pae t pae device 1 sector 2 device 1 sector 1 t pae device 1 sector 2 figure 23. paf n - direct mode - sector selection wclk t sth t sts t qh t qs 001xxx0 5939 drw25 wradd fstr device 1 sector 1 t qs t qh 001xxx1 device 1 sector 2 t qs t qh 001xxx0 device 1 sector 1 t sts t sth paf n t paf t paf device 1 sector 1 device 1 sector 3 t paf device 1 sector 1 notes: 1. sectors can be selected on consecutive cycles. 2. on an rclk cycle that the estr is high, the raden input must be low. 3. there is a latency of 1 rclk for the pae n bus to switch. notes: 1. sectors can be selected on consecutive cycles. 2. on a wclk cycle that the fstr is high, the waden input must be low. 3. there is a latency of 1 wclk for the paf n bus to switch.
41 idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits commercial and industrial temperature ranges wclk dn prev pae n rclk estr rdadd d5 sect 2 101 xxxx1 100 00100 d5q4 t ah t as t ah t as 1 t skew3 previous value loaded on to pae bus xxxx xxx0 d5 sect 2 2 raden t qh t qs t sth t sts t pae 5939 drw26 device 5 pae t rae *aa* *bb* *cc* *dd* *ff* *ee* t rae d5 qn status xxxx xxx0 d5 sect 2 bus pae n previous value loaded on to pae bus d5 sect 2 d5 sect 2 t paehz t paezl xxxx xxx1 xxxx xxx1 ren t enh t ens device 5 -qn wy d5 q4 wy+1 d5 q4 wy+3 d5 q4 wy+2 d5 q4 wa+1 d5 qn t a t a t a t a t a wa d5 qn t dh t ds wen waden fstr t ah 100 0100 t as wradd d5q4 d3q8 wn d5 q4 wn+1 d5q4 wx d3 q8 011 01000 d4 sect 1 100 xxx0 *a* *b* *c* *d* *e* *f* t qh t qs t qh t qs t ah t as t ah t as t ens t enh t sth t sts device 5 pae n 1 2 t ens t enh wp+1 wp writes to previous q t dh t ds t rae d5 q4 status figure 24. pae n - direct mode, flag operation cycle: *a* queue 4 of device 5 is selected for write operations. word, wp is written into the previously selected queue. *aa* queue 4 of device 5 is selected for read operations. a sector from another device has control of the pae n bus. the discrete pae output of device 5 is currently in high-impedance and the pae active flag is controlled by the previously selected device. *b* word wp+1 is written into the previously selected queue. *bb* word, wa+1 is read from qn of d5, due to fwft operation. *c* word, wn is written into the newly selected queue, q4 of d5. this write will cause the pae flag on the read port to go from low to high (not almost empty) after time, t skew3 + rclk + t rae (if t skew3 is violated one extra rclk cycle will be added. *cc* word, wy from the newly selected queue, q4 will be read out due to fwft operation. sector 2 of device 5 is selected on the pae n bus. q4 of device 5 will therefore have is pae status output on pae [0]. there is a single rclk cycle latency before the pae n bus changes to the new selection. *d* queue 8 of device 3 is selected for write operations. word wn+1 is written into q4 of d5. *dd* the pae n bus changes control to d5, the pae n outputs of d5 go to low-impedance and sector 2 is placed onto the outputs. the device of the previously selected sector now places its pae n outputs into high-impedance to prevent bus contention. word, wy+1 is read from q4 of d5. the discrete pae flag will go high to show that q4 of d5 is not almost empty. q4 of device 5 will have its pae status output on pae [0]. *e* no writes occur. *ee* word, wy+2 is read from q4 of d5. *f* sector 1 of device 4 is selected on the write port for the paf n bus. word, wx is written into q8 of d3. *ff* the pae n bus updates to show that q4 of d5 is almost empty based on the reading out of word, wy+1. the discrete pae flag goes low to show that q4 of d5 is almost empty based on the reading of wy+1.
42 commercial and industrial temperature ranges idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits rclk oe t olz ren raden estr wradd t ah 000 01111 t as rdadd d0q16 d0 q16 111 xxxx0 d7 sect 1 110 00010 *a* *b* *c* *d* *e* *f* 000 xxx1 t qh t qs t qh t qs t ah t as t sth t sts t sth t sts 5939 drw27 *aa* 0xxx xxxx d0sect2 device 0 paf n bus paf n *bb* *cc* *dd* *ee* *ff* t paflz 1xxx xxxx d0sect2 d0sect2 t paf t paf 0xxx xxxx 0xxx xxxx d0sect2 1xxx xxxx d0sect2 d0sect2 0xxx xxxx d x quad y prev. paf n d x quad y t pafhz high-z high-z device 0 paf high - z t paflz t waf qout d6q2 w x prev. q w d-m+1 t a d0 sect2 fstr t a wclk t skew3 w x +1 prev. q 12 d0 q16 wen t ens waden t qh t qs t ah t as t ah t as w d - m + 2 t a *g* t a d0 q16 w 0 d6 q2 t enh din t ds t dh t ds t dh t ds t dh word w y d0 q16 w y+1 d0 q16 w y+2 d0 q16 figure 25. paf n - direct mode, flag operation cycle: *a* queue 16 of device 0 is selected for read operations. the last word in the output register is available on qout. oe was previously taken low so the output bus is in low-impedance. *aa* sector 2 of device 0 is selected for the paf n bus. the bus is currently providing status of a previously selected sector, sect y of device x. *b* word, wx+1 is read out from the previous queue due to the fwft effect. *bb* queue 16 of device 0 is selected on the write port. the paf n bus is updated with the sector selected on the previous cycle, d0 sect 2. paf [7] is low showing the status of queue 16. the paf n outputs of the device previously selected on the paf n bus go to high-impedance. *c* a new sector, sect 1 of device 7 is selected for the paf n bus. word, wd-m+1 is read from q16 d0 due to the fwft operation. this read is at the paf n boundary of queue d0 q16. this read will cause the paf [7] output to go from low to high (almost full to not almost full), after a delay t skew3 + wclk + t paf . if t skew3 is violated add an extra wclk cycle. *cc* paf n continues to show status of sect 2 d0. *d* no read operations occur, ren is high. *dd* paf [7] goes high to show that d0 q16 is not almost empty due to the read on cycle *c*. the active queue paf flag of device 0 goes from high-impedance to low-impedance. word, wy is written into d0 q16. *e* queue 2 of device 6 is selected for write operations. *ee* word, wy+1 is written into d0 q16. *f* word, wd-m+2 is read out due to fwft operation. *ff* paf [7] and the discrete paf flag go low to show the write on cycle *dd* causes q16 of d0 to again go almost full. word, wy+2 is written into d0 q16. *g* word, w0 is read from q0 of d6, selected on cycle *e*, due to fwft.
43 idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits commercial and industrial temperature ranges wclk 5939 drw28 t fsync t fsync fsync 0 (master) t fxo t fxo t fsync t fsync t fxo t fxo t fsync t fsync t fxo t fxo fxo 0 / fxi 1 fsync 1 (slave) fxo 1 / fxi 2 fsync 2 (slave) fxo 2 / fxi 0 paf n t paf t paf t paf t paf t paf t paf t paf t paf t fsync t fsync d0sect1 d0sect2 d0sect1 d1sect2 d2sect1 d2sect2 d0sect1 figure 27. pae n bus - polled mode figure 26. paf n bus - polled mode note: 1. this diagram is based on 3 devices connected in expansion mode. note: 1. this diagram is based on 3 devices connected in expansion mode. rclk 5939 drw29 t esync t esync esync 0 t exo t exo t esync t esync t exo t exo t esync t esync t exo t exo exo 0 / exi 1 esync 1 exo 1 / exi 2 esync 2 exo 2 / exi 0 pae n t pae t pae t pae t pae t pae t pae t pae t pae t esync t esync d0sect1 d0sect2 d0sect1 d1sect2 d2sect1 d2sect2 d0sect1
44 commercial and industrial temperature ranges idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits figure 28. multi-queue expansion diagram notes: 1. if devices are configured for direct operation of the paf n/ pae n flag busses the fxi/exi of the master device should be tied low. all other devices tied high. the fxo/exo outputs are dnc (do not connect). 2. q outputs must not be mixed between devices, i.e. q0 of device 1 must connect to q0 of device 2, etc. wradd waden wclk wen fstr paf n fsync ff paf sclk rclk ren estr pae n esync ov pae rdadd raden so fxo exo si fxi exi wradd waden wclk wen fstr paf n fsync ff paf sclk rclk ren estr pae n esync ov pae rdadd raden so fxo exo si fxi exi wradd waden wclk wen fstr paf n fsync ff paf sclk rclk ren estr pae n esync ov pae rdadd raden seno fxo exo q 0 -q 17 si fxi exi data bus write clock write enable write queue select full strobe programmable almost full write address full sync1 full flag almost full flag serial clock output data bus read clock read enable read queue select empty strobe programmable almost empty read address empty sync 1 output valid flag almost empty flag serial programming data input device 1 device 2 device n full sync2 empty sync 2 full sync n empty sync n seno seni seno seni done 5939 drw30 d 0 -d 17 q 0 -q 17 d 0 -d 17 d 0 -d 17 q 0 -q 17 seni serial enable
45 idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits commercial and industrial temperature ranges t a p tap cont- roller mux deviceid reg. boundary scan reg. bypass reg. clkdr, shiftdr updatedr tdo tdi tms tclk trst clklr, shiftlr updatelr instruction register instruction decode control signals 5939 drw31 jtag interface five additional pins (tdi, tdo, tms, tck and trst ) are provided to support the jtag boundary scan interface. the idt72v51433/72v51443/ 72v51453 incorporates the necessary tap controller and modified pad cells to implement the jtag facility. note that idt provides appropriate boundary scan description language program files for these devices. the standard jtag interface consists of four basic elements: ? ? ? ? ? test access port (tap) ? ? ? ? ? tap controller ? ? ? ? ? instruction register (ir) ? ? ? ? ? data register port (dr) the following sections provide a brief description of each element. for a complete description refer to the ieee standard test access port specification (ieee std. 1149.1-1990). the figure below shows the standard boundary-scan architecture figure 29. boundary scan architecture test access port (tap) the tap interface is a general-purpose port that provides access to the internal of the processor. it consists of four input ports (tclk, tms, tdi, trst ) and one output port (tdo). the tap controller the tap controller is a synchronous finite state machine that responds to tms and tclk signals to generate clock and control signals to the instruction and data registers for capture and update of data.
46 commercial and industrial temperature ranges idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits test-logic reset run-test/ idle 1 0 0 select- dr-scan select- ir-scan 1 1 1 capture-ir 0 capture-dr 0 0 exit1-dr 1 pause-dr 0 exit2-dr 1 update-dr 1 exit1-ir 1 exit2-ir 1 update-ir 1 1 0 1 1 1 5939 drw32 0 shift-dr 0 0 0 shift-ir 0 0 pause-ir 0 1 input = tms 0 0 1 figure 30. tap controller state diagram refer to the ieee standard test access port specification (ieee std. 1149.1) for the full state diagram. all state transitions within the tap controller occur at the rising edge of the tclk pulse. the tms signal level (0 or 1) determines the state progression that occurs on each tclk rising edge. the tap controller takes precedence over the queue and must be reset after power up of the device. see trst description for more details on tap controller reset. test-logic-reset all test logic is disabled in this controller state enabling the normal operation of the ic. the tap controller state machine is designed in such a way that, no matter what the initial state of the controller is, the test- logic-reset state can be entered by holding tms at high and pulsing tck five times. this is the reason why the test reset ( trst ) pin is optional. run-test-idle in this controller state, the test logic in the ic is active only if certain instructions are present. for example, if an instruction activates the self test, then it will be executed when the controller enters this state. the test logic in the ic is idles otherwise. select-dr-scan this is a controller state where the decision to enter the data path or the select-ir-scan state is made. select-ir-scan this is a controller state where the decision to enter the instruction path is made. the controller can return to the test-logic-reset state other wise. capture-ir in this controller state, the shift register bank in the instruction register parallel loads a pattern of fixed values on the rising edge of tck. the last two significant bits are always required to be ?01?. shift-ir in this controller state, the instruction register gets connected between tdi and tdo, and the captured pattern gets shifted on each rising edge of tck. the instruction available on the tdi pin is also shifted in to the instruction register. exit1-ir this is a controller state where a decision to enter either the pause- ir state or update-ir state is made. pause-ir this state is provided in order to allow the shifting of instruction register to be temporarily halted. exit2-dr this is a controller state where a decision to enter either the shift- ir state or update-ir state is made. update-ir in this controller state, the instruction in the instruction register is latched in to the latch bank of the instruction register on every falling edge of tck. this instruction also becomes the current instruction once it is latched. capture-dr in this controller state, the data is parallel loaded in to the data registers selected by the current instruction on the rising edge of tck. shift-dr, exit1-dr, pause-dr, exit2-dr and update-dr these controller states are similar to the shift-ir, exit1-ir, pause-ir, exit2-ir and update-ir states in the instruction path. notes: 1. five consecutive tck cycles with tms = 1 will reset the tap. 2. tap controller does not automatically reset upon power-up. the user must provide a reset to the tap controller (either by trst or tms). 3. tap controller must be reset before normal queue operations can begin.
47 idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits commercial and industrial temperature ranges the instruction register the instruction register allows an instruction to be shifted in serially into the processor at the rising edge of tclk. the instruction is used to select the test to be performed, or the test data register to be accessed, or both. the instruction shifted into the register is latched at the completion of the shifting process when the tap controller is at update- ir state. the instruction register must contain 4 bit instruction register-based cells which can hold instruction data. these mandatory cells are located nearest the serial outputs they are the least significant bits. test data register the test data register contains three test data registers: the bypass, the boundary scan register and device id register. these registers are connected in parallel between a common serial input and a common serial data output. the following sections provide a brief description of each element. for a complete description, refer to the ieee standard test access port specification (ieee std. 1149.1-1990). test bypass register the register is used to allow test data to flow through the device from tdi to tdo. it contains a single stage shift register for a minimum length in serial path. when the bypass register is selected by an instruction, the shift register stage is set to a logic zero on the rising edge of tclk when the tap controller is in the capture-dr state. the operation of the bypass register should not have any effect on the operation of the device in response to the bypass instruction. the boundary-scan register the boundary scan register allows serial data tdi be loaded in to or read out of the processor input/output ports. the boundary scan register is a part of the ieee 1149.1-1990 standard jtag implementation. the device identification register the device identification register is a read only 32-bit register used to specify the manufacturer, part number and version of the processor to be determined through the tap in response to the idcode instruction. idt jedec id number is 0xb3. this translates to 0x33 when the parity is dropped in the 11-bit manufacturer id field. for the idt72v51433/72v51443/72v51453, the part number field con- tains the following values: device part# field (hex) idt72v51433 0x431 idt72v51443 0x432 idt72v51453 0x433 jtag instruction register the instruction register allows instruction to be serially input into the device when the tap controller is in the shift-ir state. the instruction is decoded to perform the following: ? ? ? ? ? select test data registers that may operate while the instruction is current. the other test data registers should not interfere with chip operation and the selected data register. ? ? ? ? ? define the serial test data register path that is used to shift data between tdi and tdo during data register scanning. the instruction register is a 4 bit field (i.e. ir3, ir2, ir1, ir0) to decode 16 different possible instructions. instructions are decoded as follows. jtag instruction register decoding hex instruction function value 00 extest select boundary scan register 01 sample/preload select boundary scan register 02 idcode select chip identification data register 04 high-impedance jtag 0f bypass select bypass register the following sections provide a brief description of each instruction. for a complete description refer to the ieee standard test access port specification (ieee std. 1149.1-1990). extest the required extest instruction places the ic into an external boundary- test mode and selects the boundary-scan register to be connected between tdi and tdo. during this instruction, the boundary-scan register is accessed to drive test data off-chip via the boundary outputs and receive test data off-chip via the boundary inputs. as such, the extest instruction is the workhorse of ieee. std 1149.1, providing for probe-less testing of solder-joint opens/shorts and of logic cluster function. idcode the optional idcode instruction allows the ic to remain in its functional mode and selects the optional device identification register to be connected between tdi and tdo. the device identification register is a 32-bit shift register containing information regarding the ic manufacturer, device type, and version code. accessing the device identification register does not interfere with the operation of the ic. also, access to the device identification register should be immediately available, via a tap data-scan operation, after power-up of the ic or after the tap has been reset using the optional trst pin or by otherwise moving to the test-logic-reset state. sample/preload the required sample/preload instruction allows the ic to remain in a normal functional mode and selects the boundary-scan register to be connected between tdi and tdo. during this instruction, the boundary-scan register can be accessed via a date scan operation, to take a sample of the functional data entering and leaving the ic. this instruction is also used to preload test data into the boundary-scan register before loading an extest instruction. jtag device identification register 31(msb) 28 27 12 11 1 0(lsb) version (4 bits) part number (16-bit) manufacturer id (11-bit) 0x0 0x33 1
48 commercial and industrial temperature ranges idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits high-impedance the optional high-impedance instruction sets all outputs (including two-state as well as three-state types) of an ic to a disabled (high-impedance) state and selects the one-bit bypass register to be connected between tdi and tdo. during this instruction, data can be shifted through the bypass register from tdi to tdo without affecting the condition of the ic outputs. bypass the required bypass instruction allows the ic to remain in a normal functional mode and selects the one-bit bypass register to be connected between tdi and tdo. the bypass instruction allows serial data to be transferred through the ic from tdi to tdo without affecting the operation of the ic.
49 idt72v51433/72v51443/72v51453 3.3v, multi-queue flow-control devices (16 queues) 18 bit wide configuration 589,824, 1,179,648 and 2,359,296 bits commercial and industrial temperature ranges t 4 t 3 tdo tdo tdi/ tms tck trst t do notes to diagram: t1 = t tcklow t2 = t tckhigh t3 = t tckfall t4 = t tckrise t5 = trst (reset pulse width) t6 = trsr (reset recovery) 5939 drw33 t 5 t 6 t 1 t 2 t tck t dh t ds figure 31. standard jtag timing system interface parameters parameter symbol test conditions min. max. units jtag clock input period t tck - 100 - ns jtag clock high t tckhigh -40-ns jtag clock low t tcklow -40-ns jtag clock rise time t tckrise --5 (1) ns jtag clock fall time t tckfall --5 (1) ns jtag reset t rst -50-ns jtag reset recovery t rsr -50-ns jtag ac electrical characteristics (v cc = 3.3v 5%; tcase = 0 c to +85 c) idt72v51433 idt72v51443 idt72v51453 parameter symbol test conditions min. max. units data output t do (1) -20ns data output hold t doh (1) 0-ns data input t ds t rise=3ns 10 - ns t dh t fall=3ns 10 - note: 1. 50pf loading on external output signals. note: 1. guaranteed by design.
50 corporate headquarters for sales: for tech support: 6024 silver creek valley road 800-345-7015 or 408-284-8200 408-360-1533 san jose, ca 95138 fax: 408-284-2775 email: flow-controlhelp@idt.com www.idt.com plastic ball grid array (pbga, bb256-1) low power 5939 drw34 idt xxxxx device type x power xx speed x package x process / temperature range 72v51433 589,824 bits ? 3.3v multi-queue flow-control device 72v51443 1,179,648 bits ? 3.3v multi-queue flow-control device 72v51453 2,359,296 bits ? 3.3v multi-queue flow-control device bb commercial (0 c to +70 c) industrial (-40 c to +85 c) commercial only commercial & industrial blank i (1) clock cycle time (t clk ) speed in nanoseconds 6 7-5 l ordering information note: 1. industrial temperature range product for the 7-5ns is available as a standard device. all other speed grades available by sp ecial order. datasheet document history 10/12/2001 pgs. 1, 8, 10, 14, 15, 16 and 27. 11/16/2001 pgs. 1, 4, 10, 15, 17, 18, 23, 27-30 and 32. 12/19/2001 pgs. 12 and 28. 01/15/2002 pg. 47. 04/05/2002 pgs. 7, 9, 11, 13 and 48. 07/01/2002 pgs. 2, 27 and 44. 06/04/2003 pgs. 1 through 50.


▲Up To Search▲   

 
Price & Availability of IDT72V51453L7-5BB8

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X